1999 AUDI A6 transmission

[x] Cancel search: transmission

Page 12 of 66

AUDI A6 1999 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual 01-280
 List of test steps (88-pin connector)  
 
Only perform test steps for the relevant component, as listed in DTC and Read Measuring Value Block tables.
Item checked    
Item checked    
Supply v

Page 13 of 66

AUDI A6 1999 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual 01-281
 
Item checked    
Item checked    
Solenoid valve 2 -N89-  
- Perform test steps 
10 and 8 Tiptronic switch -
F189-  - Perform test steps 26 and 27
Solenoid valve 3 -N90-  
- Perform test step

Page 14 of 66

AUDI A6 1999 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual 01-282
 Electrical test table
 
Voltage measurement: Switch multimeter to 20 V measuring range  
Test 
step  VAG  
1598/20  
sockets  Test of  
Test 
conditions 
- Additional 
steps Specified  
value

Page 17 of 66

AUDI A6 1999 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual 1) This test cannot be performed on vehicles with E-gas. The signal is transmitted from brake light switch or brake test switch 
to Engine Control Module (ECM). The ECM then forwards the signal to the

Page 20 of 66

AUDI A6 1999 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual 01-286
 
Resistance measurement: switch multimeter to 200   measuring range  
Test 
step  VAG  
1598/20  
sockets  Test of  
Test 
conditions 
- Additional 
steps Specified  
value  Corrective action

Page 21 of 66

AUDI A6 1999 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual 01-287
 
Resistance measurement: switch multimeter to 200   measuring range  
Test 
step  VAG  
1598/20  
sockets  Test of  
Test 
conditions 
- Additional stepsSpecified  
value  Corrective action

Page 23 of 66

AUDI A6 1999 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual 01-288
 
Resistance measurement: switch multimeter to 200   measuring range  
Test 
step  VAG  
1598/20  
sockets  Test of  
Test 
conditions 
- Additional stepsSpecified  
value  Corrective action

Page 25 of 66

AUDI A6 1999 C5 / 2.G 01V Transmission Electrical Testing Workshop Manual 01-289
 
Resistance measurement: switch multimeter to 200   measuring range  
Test step  
VAG  
1598/20  
sockets  Test of  
Test conditions 
- Additional stepsSpecified  
value  Corrective action  