24-93
 
  
Display fields  
  
1   2   3   4  
Display group 037: Diagnostic oxygen sensor control system  
Display  xxx %  
x.xxx volts  
xxx ms  
---  
Indicated  Engine 
load  Oxygen sensor voltage 
Bank 2, sensor 1  Dwell time, oxygen sensor control 
before catalytic converter, bank 1  Diagnostic condition  
Functional 
range    
  
  
Test OFF  
Test ON  
System OK  
System not OK  
Specified 
value  15 to 33 
%  0.100 to 0.900 V  
-150 to 150 ms  System OK  
Note  
  
If specified value is not 
obtained: Evaluation display 
field 2   Page 24
-94
   
If value climbs to above 300 ms, 
this indicates a leaking exhaust 
system or faulty oxygen sensor  If "SYST not OK" is 
displayed: Check DTC 
memory  Page 01
-16
   
Note for display field 3:  
Oxygen sensor control behind catalytic converter is superior to oxygen sensor control before catalytic converter and is 
responsible for control correction. It corrects slight changes in the mixture (i.e. toward rich or lean) due to the oxygen sensor 
before catalytic converter by holding oxygen sensor control before catalytic converter at its higher or lower point for a specific 
time (dwell time). If this time is in the positive range (i.e. 50 ms), mixture is shifted in the -enrich- direction. If this time is in the 
negative range (i.e. -50 ms), mixture is shifted in the -lean- direction. 
Pa
ge 23 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2