Page 306 of 366
01-215
Notes on display fields 3 and 4:
Display field 3 evaluates all malfunctions except "Combustion misfiring and oxygen sensor control."
Display field 4 evaluates only the malfunctions "Combustion misfiring and oxygen sensor control"
If a malfunction is recognized, the corresponding counter will be set to "40." The counter is decremented, during a new
start, when the trip was started at coolant temperature of 49 C (120 F) and ended at a water temperature of 71 C
(160 F) and the malfunction is no longer recognized. However, decrementing is only allowed if the MIL has not lit up yet
or is no longer lit. When counter status "0" is reached, the recognized malfunction is erased. If the DTC memory is erased, the counter is also decremented.
Pa
ge 306 of 366 On Board Dia
gnostic
(OBD
) - Multi
port Fuel In
jection
(MFI
)
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU01.01.1
Page 331 of 366
01-235
Notes on display field 3 and 4:
Value "0" = Diagnosis condition not fulfilled.
Value "1" = Diagnosis condition fulfilled. X
X
X
X
X
X
X
X
Meaning of 8-digit "Diagnosis condition 1"
1 = Coolant temperature: 70 - 110 C ( display group 001)
2 = Engine load: 27 - 66% ( display group 003)
3 = Engine speed: 1800 - 2700 RPM ( display group 003)
4 = Fuel throughput after engine start
[only fulfilled after approx. 3 min. trip (no idle) after start]
5 = No fuel enrichment
(during diagnosis no enrichment can occur display group 019)
6 = Closed throttle position switch open ( display group 008)
7 = Oxygen sensor control, bank 2 active ( display group 008)
8 = Oxygen sensor control, bank 1 active ( display group 007)
Pa
ge 331 of 366 On Board Dia
gnostic
(OBD
) - Multi
port Fuel In
jection
(MFI
)
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU01.01.1
Page 337 of 366
01-241
Notes on display field 3 and 4:
Value "0" = Diagnosis condition not fulfilled
Value "1" = Diagnosis condition fulfilled X
X
X
X
X
X
X
X
Meaning of 8-digit display "Diagnosis condition 1"
1 = Coolant temperature: 70 - 110 C ( display group 001)
2 = Oxygen sensor heating (all four O2S heaters; display group 040)
3 = Momentary constant drive
4 = No fuel enrichment (during diagnosis no enrichment can occur)
5 = Long-term constant drive
6 = Closed throttle position switch open ( display group 002)
7 = Oxygen sensor control, bank 2 active ( display group 008)
8 = Oxygen sensor control, bank 1 active ( display group 007)
Pa
ge 337 of 366 On Board Dia
gnostic
(OBD
) - Multi
port Fuel In
jection
(MFI
)
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU01.01.1
Page 340 of 366

01-244
Display group 099 Display
shows Display/specified
value Designation/diagnosis
Basic
setting 99
1 2 3 4 ... RPM 1 = Momentary engine speed Display group 003, display field 1 ...% 2 = Momentary engine load display group 003, display field 2
... C
3 = Coolant temperature display group 001, display field 1
-Control OFF
and/or
-Control ON
4 = Oxygen sensor control OFF in "Basic Setting" function 04; Oxygen sensor control
ON in "Read Measuring Value Block" function 08
Notes on display field 4:
For defined troubleshooting, the oxygen sensor control is switched off when display group 099 is selected under "Basic
Setting" function 04, and switched on when display group 099 is selected under "Read Measuring Value Block"function
08. When leaving "Basic Setting" function 04, oxygen sensor control is automatically active again.
You can switch back and forth between "Basic Setting" function 04 and "Read Measuring Value Block" function 08 by
pressing buttons -4- and -8- on the VAG 1551 scan tool.
Pa
ge 340 of 366 On Board Dia
gnostic
(OBD
) - Multi
port Fuel In
jection
(MFI
)
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU01.01.1
Page 347 of 366
EGR valve is closed
No coolant temperature correction; fixed value
80 C (176 F)
Learning values are relearned (idle and CO
content are adjusted automatically)
Pa
ge 347 of 366 On Board Dia
gnostic
(OBD
) - Multi
port Fuel In
jection
(MFI
)
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU01.01.1
Page 360 of 366
01-261
- Check display fields 1 and 3:
Display
field Designation
Specified
value
1 Coolant
temperature Greater than
70 C
3 Altitude display Less than 48
Note on display field 1:
If the displayed value is less than 70 C, let the
vehicle warm up until at least 70 C coolant
temperature is attained.
Note on display field 3:
If the displayed value is greater than 48
(corresponds to an altitude of approx. 1800 m) a
diagnosis of the exhaust return can not be
conducted due to altitude. Setting the readiness
code at this altitude is not possible.
If specified values are attained Step 3
Pa
ge 360 of 366 On Board Dia
gnostic
(OBD
) - Multi
port Fuel In
jection
(MFI
)
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU01.01.1