1998 NISSAN PATROL key

[x] Cancel search: key

Page 144 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual Electrical Components Inspection
KEY SWITCH (insert)
Check continuity between terminals when key is inserted in ignition
key cylinder and key is removed from ignition key cylinder.
Terminal No. Condit

Page 208 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual System Description
Power is supplied at all times
+through 40A fusible link (Letter
e, located in the fuse and fusible link box)
+to circuit breaker terminalj
1
+through circuit breaker terminalj2
+to

Page 211 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual Trouble Diagnosis
SYMPTOM CHART
REFERENCE PAGE EL-207 EL-208 EL-209 EL-210
SYMPTOM
MAIN POWER SUPPLY AND GROUND CIRCUIT CHECK
DIAGNOSTIC PROCEDURE 1
(Door lock/unlock switch check)
DIAGNOSTIC PROCEDUR

Page 216 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual System Description
OUTLINE
Power door lock system with super lock and key reminder is controlled by super lock control unit. Super lock
has a higher anti-theft performance than conventional power door

Page 217 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual Power door lock/unlock operation by lock knob
+With lock knob on driver or passenger door setting to LOCK while all doors are closed will lock all doors.
When one or more door is opened, with lock kno

Page 227 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual Trouble Diagnoses
PRELIMINARY CHECK
CHECK-IN
Open all windows and remove
key from ignition key cylinder.
Does power door lock operate
properly?
Ye s
cNo (All doors)
Power door lock does not operate by

Page 228 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual Before starting trouble diagnoses below, perform preliminary check, EL-223.
Symptom numbers in the symptom chart correspond with those of Preliminary check.
SYMPTOM CHART
REFERENCE PAGE EL-225 EL-226

Page 231 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual DIAGNOSTIC PROCEDURE 2
(Door key cylinder switch check)
CHECK DOOR KEY CYLINDER SWITCH
INPUT SIGNAL (LOCK SIGNAL).
Check voltage between control unit termi-
nalj
1and ground.
Refer to wiring diagram i