1998 DODGE RAM 1500 FRONT HUB

[x] Cancel search: FRONT HUB

Page 1802 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (10) Remove geartrain from the clutch housing and
install the geartrain into Support Stand 8246 (Fig.
30).
(11) Remove Fixture 8232 from the output shaft
and the countershaft.
(12) Separate the counte

Page 1825 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (1) Apply a light coat of Mopar high temperature
bearing grease or equivalent to contact surfaces of
following components:
²input shaft splines.
²release bearing slide surface of front retainer.
²r

Page 1835 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual AUTOMATIC TRANSMISSION -
48RE
DESCRIPTION
The 48RE (Fig. 1) is a four speed fully automatic
transmissions with an electronic governor. The 48RE
is equipped with a lock-up clutch in the torque con-
ver

Page 1838 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual PARK POWERFLOW
As the engine is running and the crankshaft is
rotating, the flexplate and torque converter, which
are also bolted to it, are all rotating in a clockwise
direction as viewed from the fr

Page 1841 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual SECOND GEAR POWERFLOW
In DRIVE-SECOND (Fig. 7), the same elements
are applied as in MANUAL-SECOND. Therefore, the
power flow will be the same, and both gears will be
discussed as one in the same. In D

Page 1847 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual DIAGNOSIS AND TESTING - AIR TESTING
TRANSMISSION CLUTCH AND BAND
OPERATION
Air-pressure testing can be used to check transmis-
sion front/rear clutch and band operation. The test
can be conducted with

Page 1848 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual TORQUE CONVERTER LEAK POINTS
Possible sources of converter leaks are:
²Leaks at the weld joint around the outside diam-
eter weld.
²Leaks at the converter hub weld.
CONVERTER HOUSING AREA LEAK CORRE

Page 1860 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual CONDITION POSSIBLE CAUSES CORRECTION
OIL LEAKS. 1. Fluid Lines and Fittings Loose/
Leaks/Damaged.1. Tighten fittings. If leaks persist, replace
fittings and lines if necessary.
2. Fill Tube (where tub