DODGE RAM 1500 1998 2.G Workshop Manual (3) Install the instrument panel top cover (Refer to
23 - BODY/INSTRUMENT PANEL/INSTRUMENT
PANEL TOP COVER - INSTALLATION).
(4) Install the left side panel duct adapter.
(5) Install the left side inte

Page 2526 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual that secure the mode door adapter to the front the
HVAC housing.
(6) Install the two screws that secure the mode
door adapter to the top of the HVAC housing.
Tighten the screws to 2.2 N´m (20 in. lbs

Page 2527 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual INSTALLATION
(1) Position the recirculation door pivot shaft into
the pivot hole in the recirculation housing.
(2) Install the recirculation door by carefully tip-
ping the door into the housing, then

Page 2529 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual REFRIGERANT OIL
DESCRIPTION.........................68
OPERATION...........................69
STANDARD PROCEDURE - REFRIGERANT
OIL LEVEL...........................69
SERVICE PORT VALVE CORE
DESCRIPTIO

Page 2535 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual After the system has been tested for leaks and
evacuated, a refrigerant (R-134a) charge can be
injected into the system.
NOTE: When connecting the service equipment
coupling to the line fitting, verif

Page 2546 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (11) Remove the tape or plugs from the discharge
line fitting and condenser inlet port.
(12) Lubricate a new rubber O-ring seal with clean
refrigerant oil and install it on the discharge line fit-
tin

Page 2547 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual REMOVAL
WARNING: ON VEHICLES EQUIPPED WITH AIR-
BAGS, DISABLE THE AIRBAG SYSTEM BEFORE
ATTEMPTING ANY STEERING WHEEL, STEERING
COLUMN, OR INSTRUMENT PANEL COMPONENT
DIAGNOSIS OR SERVICE. DISCONNECT AN

Page 2550 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (12) Reconnect the battery negative cable.
(13) Evacuate the refrigerant system (Refer to 24 -
HEATING & AIR CONDITIONING/PLUMBING -
STANDARD PROCEDURE - REFRIGERANT SYS-
TEM EVACUATE).
(14) Charge th