1998 DODGE RAM 1500 Y case

[x] Cancel search: Y case

Page 2034 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (31) Install the output shaft selective thrust plate
onto the reaction annulus with the oil grooves facing
the annulus gear and the tabs and notches aligned as
shown in (Fig. 42).
(32) Install the num

Page 2035 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual visual inspection through the input speed sensor
hole. If the tone wheel teeth on the input clutch
assembly are centered in the hole, the assembly is
fully installed.
(42) Install the number 1 bearing

Page 2036 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (46) Install the transmission front cover into the
transmission case (Fig. 48).
(47) Install the outer snap-ring to hold the trans-
mission front cover into the transmission case (Fig.
48).
(48) Parti

Page 2038 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (16) Install transfer case, if equipped. Tighten
transfer case nuts to 35 N´m (26 ft.lbs.).
(17) Install rear support to transmission. Tighten
bolts to 47 N´m (35 ft.lbs.).
(18) Lower transmission o

Page 2039 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (22) Install torque converter-to-driveplate bolts.
Tighten bolts to 31 N´m (270 in. lbs.).
(23) Install starter motor and cooler line bracket.
(24) Connect cooler lines to transmission.
(25) Install

Page 2061 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual SPECIFICATIONS
TRANSMISSION
GENERAL
Component Metric Inch
Output Shaft End Play 0.22-0.55
mm0.009-0.021
in.
Input Shaft End Play 0.46-0.89
mm0.018-0.035
in.
2C Clutch Pack
Clearance0.455-1.335
mm0.018

Page 2067 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual ADAPTER HOUSING SEAL
REMOVAL
(1) Remove the transfer case from the transmis-
sion.
(2) Using a screw mounted on a slide hammer,
remove the adapter housing seal.
INSTALLATION
(1) Clean the adapter seal

Page 2069 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual FLUID AND FILTER
DIAGNOSIS AND TESTING
DIAGNOSIS AND TESTING - EFFECTS OF
INCORRECT FLUID LEVEL
A low fluid level allows the pump to take in air
along with the fluid. Air in the fluid will cause fluid