1998 DODGE RAM 1500 Drive shaft

[x] Cancel search: Drive shaft

Page 2504 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (4) Reconnect the battery negative cable.
BLEND DOOR ACTUATOR
DESCRIPTION
The blend door actuators are reversible, 12-volt
Direct Current (DC), servo motors. Models with the
single zone heater and air

Page 2507 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual BLOWER MOTOR SWITCH
DESCRIPTION
The blower motor is controlled by a rotary-type
blower motor switch, mounted in the A/C-heater con-
trol. The switch allows the selection of one of four
different blowe

Page 2510 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (2) Assemble the HVAC housing (Refer to 24 -
HEATING & AIR CONDITIONING/DISTRIBUTION/
HVAC HOUSING - ASSEMBLY).
(3) Connect the HVAC wire harness connector to
the evaporator temperature sensor.
(4) In

Page 2511 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual RECIRCULATION DOOR
ACTUATOR
DESCRIPTION
The recirculation door actuator is a reversible
12-volt Direct Current (DC) servo motor. The single
recirculation door actuator is located on the passen-
ger si

Page 2512 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (2) Remove the instrument panel from the vehicle
(Refer to 23 - BODY/INSTRUMENT PANEL/IN-
STRUMENT PANEL CENTER BEZEL - REMOVAL).
(3) Disconnect the wire harness connector from the
recirculation door

Page 2514 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual NOTE: The instrument panel air outlets are retained
into the outlet housings by a light snap fit.
(1) Using a trim stick or another suitable wide
flat-bladed tool, gently pry the panel air outlet(s) o

Page 2522 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual DISASSEMBLY
(1) Remove the HVAC housing from the vehicle
and place it on the workbench (Refer to 24 - HEAT-
ING & AIR CONDITIONING/DISTRIBUTION/HVAC
HOUSING - REMOVAL).
(2) Disconnect the electrical c

Page 2564 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual Immediately after a cold start, between predeter-
mined temperature thresholds limits, the three port
solenoid is briefly energized. This initializes the
pump by drawing air into the pump cavity and a