1998 DODGE RAM 1500 Over drive

[x] Cancel search: Over drive

Page 1664 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (17) Remove the steering column assembly from
the vehicle. (Fig. 7)
INSTALLATION
WARNING: BEFORE SERVICING THE STEERING
COLUMN THE AIRBAG SYSTEM MUST BE DIS-
ARMED. REFER TO ELECTRICAL RESTRAINT SYS-

Page 1667 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual KEY CYLINDER
REMOVAL
The ignition key must be in the key cylinder for
cylinder removal.
(1) Disconnect negative cable from battery.
(2) Remove upper and lower covers (shrouds) from
steering column.
(3

Page 1668 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (2) Cycle the key from ACC to RUN and ensure
that the blocker does not stick or bind.
(3) Turn the key to the OFF position and ensure
that the shifter will not pull from the PARK position.
(4) Connect

Page 1681 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual NOTE: Tighten the slide hammer adapter 8990 into
the seal using wrenches, in order to make a tight fit
to pull the seal out. If this is not performed the seal
may tear on the removal making it difficu

Page 1685 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (7) Install the input shaft seal protector 8986 (Fig.
20).
(8) Coat the new seal inhigh temp greaseand
Install the new oil seal using special tool 8987 driver
and C-4171 handle (Fig. 21).
NOTE: Drive

Page 1694 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual PUMP
TABLE OF CONTENTS
page page
PUMP
DESCRIPTION.........................39
OPERATION...........................40
DIAGNOSIS AND TESTING - PUMP LEAKAGE . 40
STANDARD PROCEDURE
STANDARD PROCEDURE - PO

Page 1695 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual OPERATION
Hydraulic pressure is provided for the power steer-
ing gear by the belt driven power steering pump (Fig.
1). The power steering pumps are constant flow rate
and displacement, vane-type pump

Page 1698 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual FLUID
DESCRIPTION
The recommended fluid for the power steering sys-
tem is MopartATF +4.
MopartATF+4, when new is red in color. The
ATF+4 is dyed red so it can be identified from other
fluids used in