DODGE RAM 1500 1998 2.G Workshop Manual (15) Rotate pinion several times then verify pinion
rotating torque again.
(16) Position the ring gear on differential case and
start twonewring gear bolts.
(17) Install the rest of thenewring gear bo

Page 248 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (21) Install differential in housing and verify gear
backlash and gear contact pattern.
(22) Measure final rotating torque with an inch
pound torque wrench. The final pinion rotating
torque plus diffe

Page 279 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual HYDRO-BOOST BRAKE
BOOSTER
DIAGNOSIS AND TESTING - HYDRAULIC
BOOSTER
The hydraulic booster uses hydraulic pressure from
the power steering pump. Before diagnosing a
booster problem, first verify the po

Page 296 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual FRONT WHEEL SPEED
SENSOR
DESCRIPTION
The ABS brake system uses 3 wheel speed sensors.
A sensor is mounted to each front hub/bearings. The
third sensor is mounted on top of the rear axle dif-
ferential

Page 302 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual CLUTCH
TABLE OF CONTENTS
page page
CLUTCH
WARNING.............................1
DIAGNOSIS AND TESTING................1
SPECIFICATIONS........................5
CLUTCH DISC
REMOVAL......................

Page 312 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual Common causes of runout are:
²heat warpage
²improper machining
²incorrect bolt tightening
²improper seating on crankshaft flange shoulder
²foreign material on crankshaft flange
Flywheel machining

Page 415 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual During Closed Loop modes, the PCM will monitor
the oxygen (O2S) sensors input. This input indicates
to the PCM whether or not the calculated injector
pulse width results in the ideal air-fuel ratio. T

Page 416 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual IDLE MODE
When the engine is at operating temperature, this
is a Closed Loop mode. At idle speed, the PCM
receives inputs from:
²Air conditioning select signal (if equipped)
²Air conditioning reques