DODGE RAM 1500 1998 2.G Workshop Manual STATOR
The stator assembly (Fig. 230) is mounted on a sta-
tionary shaft which is an integral part of the oil
pump. The stator is located between the impeller and
turbine within the torque converter c

Page 1962 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual OPERATION
The converter impeller (Fig. 233) (driving member),
which is integral to the converter housing and bolted
to the engine drive plate, rotates at engine speed.
The converter turbine (driven me

Page 1963 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual STATOR
Torque multiplication is achieved by locking the
stators over-running clutch to its shaft (Fig. 234).
Under stall conditions the turbine is stationary and
the oil leaving the turbine blades st

Page 1964 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (6) Check converter seating with a scale and
straightedge (Fig. 235). Surface of converter lugs
should be 19mm (0.75 in.) to the rear of the straight-
edge when converter is fully seated.
(7) If neces

Page 1969 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (7) Remove the TRS mounting bracket (Fig. 244)
from the transmission case.
INSTALLATION
(1) Move the transmission manual shaft lever to
the manual LOW position.
(2) Install the TRS mounting bracket in

Page 1970 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual TRANSMISSION
TEMPERATURE SENSOR
DESCRIPTION
Transmission fluid temperature readings are sup-
plied to the transmission control module by the ther-
mistor (Fig. 248). The temperature readings are used

Page 1976 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual REGULATOR VALVE
The pressure regulator valve is needed to control
the hydraulic pressure within the system and reduce
the amount of heat produced in the fluid. The pres-
sure regulator valve is locate

Page 1977 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual Meanwhile, the torque converter is filled slowly. In
all other gear positions (Fig. 254), fluid flows
between two right side lands to the switch valve and
torque converter. At low pump speeds, the flo