1998 DODGE RAM 1500 Control module

[x] Cancel search: Control module

Page 518 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual INDICATORS
Indicators are located in various positions within
the EMIC and are all connected to the EMIC elec-
tronic circuit board. The cargo lamp indicator, door
ajar indicator, high beam indicator,

Page 520 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual CAUTION: Instrument clusters used in this model
automatically configure themselves for compatibil-
ity with the features and optional equipment in the
vehicle in which they are initially installed. Th

Page 521 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual ACTUATOR TEST
WARNING: TO AVOID PERSONAL INJURY OR
DEATH, ON VEHICLES EQUIPPED WITH AIRBAGS,
DISABLE THE SUPPLEMENTAL RESTRAINT SYS-
TEM BEFORE ATTEMPTING ANY STEERING
WHEEL, STEERING COLUMN, AIRBAG,

Page 527 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual Each time the ABS indicator fails to light due to an
open or short in the cluster ABS indicator circuit, the
cluster sends a message notifying the CAB of the
condition, then the instrument cluster and

Page 530 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual cluster programming, a hard wired multiplex input
received by the cluster from the headlamp panel
lamps dimmer switch on the headlamp dimmer
switch mux circuit, and electronic unlock request
messages

Page 531 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual ²Engine Temperature High Message- Each
time the cluster receives a message from the PCM or
ECM indicating the engine coolant temperature of a
gasoline engine is about 122É C (252É F) or higher, or

Page 533 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual ENGINE TEMPERATURE
GAUGE
DESCRIPTION
An engine coolant temperature gauge is standard
equipment on all instrument clusters. The engine
coolant temperature gauge is located in the lower
right quadrant o

Page 534 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual ²Actuator Test- Each time the cluster is put
through the actuator test, the engine coolant temper-
ature gauge needle will be swept to several calibra-
tion points on the gauge scale in a prescribed