Fiber Optic Light Conductor Cable:The fiber optic cables carry the light to their respec-
tive light output modules at each exterior door handle. 
Installation Note:The bending radius of the fiber optic cable should be less than 20mm
when installing.
Light  Output  Modules: The  exterior  door  handle  frames  have  an  additional  mount  to
accept the light output module. 
The light output modules carry the light from the conductor cables to the exterior door han-
dle recess as well as casting a soft exterior light on the outside floor area. 
Principle of Operation
Lights ON:
The exterior visual entry aid lighting is activated “on” when the vehicle interior 
lights are activated “on” automatically by the GM.
Lights OFF:
Immediately after KL 15 recognition (immediate off - no soft off function). Soft 
off after a short delay once all doors are closed.
After a maximum of 20 seconds “on” time, the control module switches exterior visual entry
aid lighting off regardless of interior light status.
57
Central Body Electronics ZKE III
615200131.eps 
General Functions of ZKE III
Consumer Cut Off
The Consumer Cut Off function interrupts battery voltage to circuits preventing inadvertent
battery  drain  if  one  of  these  consumers  were  to  remain  activated.  Circuits  controlled  by
consumer cut off will be switched off as the GM enters into the sleep mode.
For example, the interior lights are connected to the consumer cut out circuit (KL 30) and
can  remain  on  if  one  of  the  control  switches  are  left  on.  The  consumer  cut  off  will  deacti-
vate KL 30 to the interior lighting after 16 minutes (or with the DISplus/MoDIC).
The  following  circuits  are  con-
trolled by consumer cut off:
• Map/Reading Lights
• Glove Box/Luggage Compart- 
ment Lights
• Transmission Range Indicator  
Light
• Overload Protection Relay for
- Power Seat Motors
- Steering Column Motors
Overload Protection
The seat and steering column motors receive
operating  power  through  the  consumer  cutoff/
overload protection relay module. The consumer
cutoff  signal  from  the  GM  signals  the  relay  to
maintain operating power to the consumers. 
If the relay module detects an increase in amper-
age (overload) the relay will open. The relay mod-
ule  (K-72)  is  located  in  the  electrical  carrier
behind  the  glove  box.  The  relay  is  reset  by
switching  the  ignition  “off”  for  16  minutes,  dis-
connecting the relay or the DISplus/ MoDIC. 
75
Central Body Electronics ZKE III
E38 Shown
Overload
Protection Relay
Module