Page 25 of 38
24-114
- Press buttons -0-, -0- and -3- to input display
group number 3, and press -Q- button to confirm
input. Read Measuring Value Block 3 1 2 3 4
Indicated on display (1-4 = display fields)
- Compare display with specified values for throttle angle, (display field
3):
Display fields
1 2 3 4
Display group 3: Load measurement
Display xxx RPM xx.x g/s
xxx
xx.x BTDC
Indicates Engine speed
(in 40 RPM
steps) Mass air
flow Throttle angle Ignition timing
Range 0-6800 RPM ---
0-90
0.0 -50.0
BTDC
Specified
value 0 RPM ---
0-5
0.0
--- --- If not as specified Page 24
-115
, Evaluating display
group 3
---
-
Open throttle valve slowly while monitoring degree ( ) value in display field 3. Value must increase uniformly over the entire range.
Pa
ge 25 of 38 Throttle valve control module, checkin
g
11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.24.2
Page 27 of 38
24-115
- Press buttons -0- and -6- to select "End Output"
function 06, and press -Q- button to confirm
input.
- Switch ignition off.
Note:
The values displayed in display field 3 depend on
the calibration of the Throttle Position (TP)
sensor and do not correspond with the actual
throttle valve opening in degrees. The maximum
displayed value is 90.0 . If the throttle angle value does not increase
uniformly:
- Replace throttle valve control module -J338-.
- Carry out adaptation of throttle valve control
module to ECM Page 24
-119
.
- Check readiness code Page 01
-59
. If
Diagnostic Trouble Code (DTC) memory has
been erased, or ECM was disconnected,
generate new readiness code Page 01
-62
.
Evaluating display group 3
Pa
ge 27 of 38 Throttle valve control module, checkin
g
11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.24.2
Page 28 of 38
Display group: 3
Display field: 3
Possible cause
Corrective action
0.0
Open circuit in wiring- Check wiring Page 24
-116
99.0
Short circuit to ground (GND)
Pa
ge 28 of 38 Throttle valve control module, checkin
g
11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.24.2
Page 35 of 38

24-120
Test procedure
- Connect VAG 1551 or VAG 1552 scan tool and
press buttons -0- and -1- to insert "Engine
Electronics" address word 01 (with ignition
switched on; engine not running) Page 01
-7 .
Rapid data transfer
HELP
Select function XX
Indicated on display
- Press buttons -0- and -4- to select "Basic Setting" function 04, and
press -Q- button to confirm input.
System in Basic Settin
g
HELP
Input displa
y group number XXX
Indicated on display
- Press buttons -0-, -6- and -0- to input display group number 60, and
press -Q- button to confirm input.
System in Basic Setting 60 1 2 3 4
Indicated on display (1-4 display fields)
Note:
After confirming input of display group 60, adaptation is started. The
Throttle Position (TP)sensor is positioned in the closed throttle, wide
open throttle and limp-home positions. Following this procedure, other
intermediate steps will create a characteristic curve of the relationship
between Throttle Position (TP) sensor -G69- and angle sensor for
throttle drive -G187-. The Motronic ECM stores these values in permanent memory.
Afterward, the throttle valve assumes the starting position.
Pa
ge 35 of 38 Throttle valve control module, checkin
g
11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.24.2
Page 36 of 38
24-121
- Compare display with specified values (display
fields 1-4):
Display fields
1 2 3 4
Display group 60: Basic setting-throttle valve control module
Display
xxx
xxx
Idle
Part throt
Full throt
Decel
Enrich ADP runs
ADP. OK
ADP. ERROR
Indicates Throttle valve
angle Throttle drive
angle Operating
condition Adaptation condition
Range
0-90
--- ---
Specified
value 0-5 Idle ADP. runs
ADP. OK
(ADP. ERROR indicates unsuccessful
adaptation)
If displayed values are NOT OK:
- Check DTC memory ( Page 01
-15
)
Pa
ge 36 of 38 Throttle valve control module, checkin
g
11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.24.2
Page 38 of 38
24-122
If displayed values are OK:
- Allow at least 30 seconds.
- End adaptation as soon as possible after 30
seconds by pressing button.
- Press buttons -0- and -6- to select "End Output"
function 06, and press -Q- button to confirm
input.
Pa
ge 38 of 38 Throttle valve control module, checkin
g
11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.24.2