Page 38 of 79
24-35
If residual pressure sinks below 2.5 bar positive
pressure:
- Start engine and let run at idle.
If pressure does not drop now:
If pressure drops again:
If pressure does not drop now: - Wait until pressure has dropped, and then switch off ignition.
Simultaneously close shut-off valve of VAG1318 pressure gauge (lever
perpendicular to direction of flow -arrow-).
- Observe pressure drop on pressure gauge.
- Test check-valve on Fuel Pump (FP).
- Open shut-off valve of pressure gauge. The lever points in the direction
of flow.
- Start engine and let run at idle.
- Wait until pressure has dropped, and then switch off ignition.
Simultaneously clamp return line (with blue marking) completely
closed.
- Replace fuel pressure regulator
Pa
ge 38 of 79 Motronic in
jection s
ystem, servicin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.1
Page 42 of 79
24-39
Checking voltage supply
Test requirements:
Fuse for fuel injectors OK
Electrical Wiring Diagrams, Troubleshooting &
Component Locations
Fuel Pump (FP) relay OK; checking Page 24
-52
.
- Disconnect harness connector at the fuel
injector to be tested.
If LED does not light up: - Connect VAG1527B voltage tester as follows:Harness connector
Terminal
Measure to
1 Engine Ground (GND)
- Switch ignition on.
LED must light up.
Pa
ge 42 of 79 Motronic in
jection s
ystem, servicin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.1
Page 53 of 79
24-49
Test requirement:
Fuel pressure OK, checking Page 24
-32
.
Test sequence
- Remove fuel distributor including fuel injectors
from intake manifold Page 24
-45
. Fuel lines
remain connected.
- Connect VAG1598/31 test box at wiring harness
to Engine Control Module (ECM), do not connect
ECM Page 24
-19
.
Checking Proper Seal
- Bridge terminals 1 and 65 at test box using wires
from VAG1594A adapter test kit.
- Switch ignition on.
Fuel Pump (FP) must run.
- Check proper seal of fuel injectors (visual
inspection). With Fuel Pump (FP) running, only 1
to 2 drops per minute may drip out per injector.
-
If fuel loss is greater, stop Fuel Pump (FP) from
Pa
ge 53 of 79 Motronic in
jection s
ystem, servicin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.1
Page 54 of 79
running (switch off ignition) and replace faulty
fuel injector Page 24
-45
.
Pa
ge 54 of 79 Motronic in
jection s
ystem, servicin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.1
Page 55 of 79
24-50
Checking Injection Quantity
- Insert fuel injector to be tested in a measuring
glass from VAG1602 injection quantity test
device.
- Connect one terminal of fuel injector to engine Ground (GND) using an
adapter cable and an alligator clip from VAG1594A connector test kit.
- Connect the second terminal of fuel injector to B+ using VAG1348/3A
remote control, VAG1348/3-2 adapter cable and assisting cable.
- Bridge terminals 1 and 65 at test box using wires from VAG1594A
adapter test kit.
- Bridge terminals 1 and 65 at test box using wires from VAG1594A
adapter test kit.
- Switch ignition on.
Fuel Pump (FP) must run.
- Activate VAG1348/3A remote control for 30 seconds.
- Perform measurement on all fuel injectors.
Pa
ge 55 of 79 Motronic in
jection s
ystem, servicin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.1
Page 56 of 79
24-51
- After all four fuel injectors have been activated,
place measuring glasses on an even surface.
Specified value for each fuel injector: 135
10 ml
- If measured value of one or more fuel injectors
is outside of specified range, switch Fuel Pump
(FP) off (switch ignition off) and replace faulty
fuel injector Page 24
-45
.
- If the measured values of all fuel injectors are
outside the specified range, check fuel pressure
Page 24
-32
.
Note:
Also check spray pattern when checking injection
quantity. Spray pattern must be the same for all
injectors
- Install fuel injectors together with fuel distributor
Page 24
-46
.
Pa
ge 56 of 79 Motronic in
jection s
ystem, servicin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.1
Page 58 of 79
24-53
Component location Overview of component
locations Page 24
-5
Voltage is supplied to the Fuel Pump (FP) and
several components of the injection system via
the Fuel Pump (FP) relay -J17-.
Engine must be turning for Fuel Pump (FP) relay
-J17- to close. This means that the relay does
not receive Ground (GND) (via ECM) until the
ECM recognizes RPM signals.
Test requirement:
Battery voltage at least 12.7 V
Function test of Fuel Pump (FP) relay
- Remove driver-side storage compartment.
Repair Manual, Body Interior, Repair Group
68
- Connect VAS5051 tester Page 01
-7 and
select vehicle system "01 - Engine electronics".
Ignition must remain switched on for this.
-
Initiate output Diagnostic Test Mode (DTM)
Page 01
-51
and activate Evaporative Emission
Pa
ge 58 of 79 Motronic in
jection s
ystem, servicin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.1
Page 61 of 79
24-55
If specified value is not obtained:
- Replace central electronics.
Checking activation of Fuel Pump (FP) relay
- Switch ignition off.
- Connect VAG1598/31 test box at wiring harness
to Engine Control Module (ECM), do not connect
ECM Page 24
-19
.
- Switch ignition on.
- Bridge terminals 1 and 65 at test box using wires
from VAG1594A adapter test kit.
If relay triggers now, but didn't during output DTM:
If relay does not trigger:
Fuel Pump (FP) relay (at position 4 of central electronics in driver's
footwell, left) must trigger.
- Replace Engine Control Module (ECM) Page 24
-22
- Switch ignition off.
- Remove cable bridge.
Pa
ge 61 of 79 Motronic in
jection s
ystem, servicin
g
11/22/2002 htt