Page 256 of 363
JSA051.0
INJECTION
Fault finding - Checking conformity
17
D7F 710
engine -
55 tracks
Engine warm, at idle speed, after fan assembly has operated at least once (air
conditioning not selected)NOTES
Order of
operationsFunction to be
checkedAction Bargraph Display and notes
4
(cont)Interpretation of
normally illuminated
bargraphs (cont)
-
Fuel pump active
Always illuminated if air
conditioning option available
Illuminates after erasing the
memory to indicate that the
operation has been carried out
correctly
Computer configured for:
Manual gearbox (G50*2*)
Automatic
transmission(G50*1*)
7
19
9
19
12
17-213
Page 257 of 363
JSA051.0
INJECTION
Fault finding - Checking conformity
17
D7F 710
engine -
55 tracks
NOTES
Order of
operationsFunction to be
checkedAction Bargraph Display and notes
5 Engine idle speed Without air
conditioning
# 06
# 12
# 44
With air
conditioning
and without
fast idle
request
# 06
# 44
With air
conditioning
and fast idle
request
# 06
# 44X = 740 ± 50 rpm
4 % < X < 14 %
X ≈ 300 W
X = 740 ± 50 rpm
300 ≤ X ≤ 4000 W
X = 850 ± 50 rpm
300 ≤ X ≤ 4000 W
6Anti-pinking noise
measurement# 13
(3500 rpm, no
load) X variable and not zero
Engine warm, at idle speed, after fan assembly has operated at least once (air
conditioning not selected)
6
9
9
10
9
10
17-214
Page 258 of 363
JSA051.0
INJECTION
Fault finding - Checking conformity
17
D7F 710
engine -
55 tracks
NOTES
Order of
operationsFunction to be
checkedAction Bargraph Display and notes
7 Manifold pressure# 01
no consumers X is variable and is
approximately
270 ≤ X ≤ 430 mb
(this pressure varies with
altitude)
8 Richness regulation Stable engine
speed of 2500
rpm then idle
speed
# 05
# 35X varies in the range from 50 to
900 mV approximately
X is close to 128 and varies
slightly
with a maximum of 255
and minimum of 0
9Adaptive idle speed
correction# 21- 4.3 % < X < 3.9 %
(average value after erasing
the memory : 0)
10 Canister bleed# 23Canister bleed is prevented.
The solenoid valve remains
closed. X = 0.7 %
11 PAS pressostat# 06X = 800 rpm
Engine warm, at idle speed, after fan assembly has operated at least once (air
conditioning not selected)
6
6
11
13
17-215
Page 259 of 363

JSA051.0
INJECTION
Fault finding - Checking conformity
17
D7F 710
engine -
55 tracks
Checks to be carried out during a road test.NOTES
Order of
operationsFunction to be
checkedAction Bargraph Display and notes
1 Change to status testG01*
10.NJ
Use fiche n° 27
status test side
2 No fault presentEnsure this bargraph is not
flashing, otherwise enter
G02* and turn over the fiche.
IMPORTANT: This bargraph
may flash if the vehicle has no
immobiliser. Ignore this
bargraph if fault bargraph 2 RH
side is illuminated and *22 = 2
dEF.
Repair the faulty component
the erase the memory (G0**)
and return to the status test
(G01*)
3 Canister bleed# 23Canister bleed is authorised
X = variable and > 0.7
4Vehicle speed
information# 18X = vehicle speed read on
speedometer
5 Pinking sensor Vehicle under
load and
engine speed
2000 rpm
# 13
# 15X = variable and not zero
0 ≤ X ≤ 6
(if there is a sensor fault, the
advance is retarded
systematically by 4° , which is
not visible using # 15)
11
20
17-216
Page 260 of 363
JSA051.0
INJECTION
Fault finding - Checking conformity
17
D7F 710
engine -
55 tracks
Checks to be carried out during a road test.NOTES
Order of
operationsFunction to be
checkedAction Bargraph Display and notes
6 Adaptive richness After
programming
phase
# 30
# 31 106 ≤ X ≤ 150
(average value after erasing
the memory : 128)
106 ≤ X ≤ 150
(average value after erasing
the memory : 128)
17-217
Page 262 of 363

B76531.0
ELECTRONICALLY CONTROLLED HYDRAULIC SYSTEMS
Fault finding - Introduction38
ABS BOSCH
5.3
CONDITIONS FOR APPLICATION FOR THE TESTS DEFINED IN THIS FAULT FINDING
The tests described in this fault finding are only to be applied when the wording of the fault corresponds
exactly to the display on the XR25 kit.
If a fault is dealt with because there is a flashing bargraph, the conditions for confirming the existence of an
actual fault (and the need to apply the fault finding ) can be found in the "Notes" or at the beginning of the
bargraph interpretation.
If a bargraph is only interpreted when it is permanently illuminated, the application of the recommended
tests in the fault finding when the bargraph is flashing will not allow you to determine the origin of the
memorisation of this fault. In this case, only a test of the wiring and the connections of the component in
question must be carried out (the fault is simply memorised as it was not present at the time of testing).
NOTE : The ignition must have been switched off before the XR25 kit is used.
INDISPENSABLE TOOLING REQUIRED FOR OPERATIONS ON THE ABS SYSTEM
- XR25 kit.
- XR25 cassette n° 16 minimum.
Reminders :When there is intermittent fault memorisation, the ABS warning light will illuminate the next
time the vehicle is used until the car reaches 7.5mph (12 km/h). When the fault is memorised, a
counter relating to the fault is set at 40 . This value is reduced by one each time the ignition is
turned on if the fault is not present when the vehicle exceeds 7.5mph (12 km/h). When the
reading on the counter is equal to 1, it remains at 1 and the fault is not erased.
38-1
Page 264 of 363

B76531.0
ELECTRONICALLY CONTROLLED HYDRAULIC SYSTEMS
Fault finding- Fiche XR2538
ABS BOSCH
5.3
SYMBOLISATION OF THE BARGRAPHS
- Of faults (always on coloured background) :
If illuminated, signals a fault on the product tested. The associated text
describes the fault.
This bargraph may be:
- Illuminated : fault present.
- flashing : fault memorised.
- Extinguished : fault absent or not found.
- Of status (always on white background) :
Bargraph is always on the upper right hand side
If illuminated, this signals the establishment of dialogue with the product computer
If it remains extinguished :
- The code does not exist.
- There is a fault in the XR25, the computer or the XR25/computer connection.
The representation of the following bargraphs indicates their initial status:
Initial status : (ignition on, engine stopped, without operator action).
Indefinite
illuminated when the function or condition specified on the fiche is
met
Extinguished
Illuminated extinguished when the function or condition specified on the fiche is
no longer met.
- Supplementary information:
Certain bargraphs have a *. Command*.., when the bargraph is illuminated, allows supplementary
information on the type of fault or status arising to be displayed.
or
38-3
Page 279 of 363
B76531.0
ELECTRONICALLY CONTROLLED HYDRAULIC SYSTEMS
Fault finding - Conformity Check38
ABS BOSCH
5.3
Order of
operationsFunction to be checked Action Bargraph Display and Comments
1 XR25 dialogueD11
(selector on
S8)
2 Computer conformity#12
3
Operation of ABS warning
light- computer
initialisation check
IgnitionTwo second illumination of
warning light when ignition is
switched on (consult fault
finding if it remains illuminated
or if it does not illuminate)
4Acknowledgement that
brake pedal is not
pressed
5Acknowledgement that
brake pedal is pressedPress brake
pedal
Only carry out this conformity check after a complete XR25 check.NOTES
13
13
38-18