Page 332 of 363

v0406.0
IMMOBILISER
Fault finding - Checking conformity
82
If a fault bargraph illuminates, refer to the corresponding fault chart.NOTES
Order of
operationsFunction to be
checkedAction Bargraph Display and notes
5Configuration of the
computer -
petrol/dieselIlluminated if configured for a
diesel vehicle.
Extinguished if configured for
a petrol vehicle.
Command :
-G22*1* configuration for
petrol.
-G22*2* configuration
for diesel.
6 Forced protection
modeIlluminated only after entering
command G04* on the XR25.
Vehicle cannot be started as
long as
BG 9LH is illuminated.
7Immobiliser statusIlluminated if immobiliser
active : switch off the ignition
and wait approximately 10
seconds for the
BG 10LH to
illuminate.
Extinguished if immobiliser
inactive.
8Presence of the keyIlluminated when the ignition
is switched on if the key is
coded
(on condition that the vehicle
was protected before the
ignition was switched on,
immobiliser warning light
flashing).
NOTE : in normal operation,
bargraphs
8RH, 9 RH and 10 RH should be
illuminated together.
3
9
10
8
82-35
Page 333 of 363

v0406.0
IMMOBILISER
Fault finding - Checking conformity
82
If a fault bargraph illuminates, refer to the corresponding fault chart.NOTES
Order of
operationsFunction to be
checkedAction Bargraph Display and notes
9Reception of the key
codeIlluminated when the ignition
is switched on
if the key is coded and has the
correct format (on condition
that the vehicle was protected
before the ignition was
switched on, immobiliser
warning light flashing).
NOTE : In normal operation ,
bargraphs
8RH , 9RH and 10RH should be
illuminated together.
10 Valid key code Illuminated when the ignition
is turned on if the key is coded
and has the correct format and
code (on condition that the
vehicle was protected before
the ignition was turned on,
immobiliser warning light
flashing).
NOTE: In normal operation
bargraphs 8RH, 9RH and 10RH
should be illuminated
together.
11Reception of the
infrared signal from
the PLIP Illuminated for approximately
3 seconds if the infrared signal
is received by the decoder unit
via the infrared transmitter.
Illuminated for approximately
3 seconds if the infrared signal
received by the decoder unit
via the infrared transmitter is
the correct signal.
9
10
11
11
82-36
Page 335 of 363
v0406.0
IMMOBILISER
Fault finding - Checking conformity
82
If a fault bargraph illuminates, refer to the corresponding fault chart.NOTES
Order of
operationsFunction to be
checkedAction Bargraph Display and notes
16Information on
programming or
resynchronisation of
PLIP in progressIlluminated if programming or
resynchronisation in progress
(PLIP).
17Programming not
carried out for PLIP
informationIlluminated if programming
not carried out (PLIP).
18 Programming of 1st
key informationNot used.
19 Programming not
carried out for key
informationIlluminated if programming
not carried out (key).
20Programming not
confirmed for key
informationIlluminated if programming
not confirmed (key).
G60* : changes to 1 when
setting is completed.
21Sending of
information is blocked
Enter security code
17
18
19
17
19
20
82-38
Page 336 of 363

v0406.0
IMMOBILISER
Fault finding - Aid
82
ADDITIONAL CHECKS
COMMAND MODES G--*
To use this function, enter G on the XR25 , then the number of the command followed by a star.
03Courtesy light control (Illuminates the courtesy light for 3 seconds).
04Forced protection mode : activates the immobiliser function even if the key is correct, which allows
starting prevention to be checked. Bargraph 9 left should illuminate.
This command must be entered when the ignition is off and the immobiliser function is active.
IMPORTANT: switching the ignition off cancels this command.
05Immobiliser warning light command (illuminates immobiliser warning light for 3 seconds ).
08Door unlock command (activates micromotors on unlock side for 3 seconds ).
09Door lock command (activates micromotors on lock side for 3 seconds ) .
13End of fault finding.
22Configuration :
-G 22 * 1 * = configuration for petrol vehicles (Bargraph 3RH should be extinguished).
-G 22 * 2 * = configuration for diesel vehicles (Bargraph 3RH should be illuminated).
23Forced solenoid valve test mode (used only on diesel vehicles).
Activates coded solenoid valve (opening/closing) for approximately 30 seconds (listen).
Note: - the decoder unit must be configured for a diesel vehicle
- Bargraph 8 left should be illuminated during the test.
32Programming of second PLIP key.
39Transponder line.
82-39