1997 MERCEDES-BENZ ML320 air condition

[x] Cancel search: air condition

Page 3430 of 4133

MERCEDES-BENZ ML320 1997  Complete Repair Manual Fig. 156: Identifying Quick Test On Air Conditioning System - Shown On Models 901, 902, 903, 904 
Shown on models 901, 902, 903, 904  
 Prerequisites for 
testing  
1Place vehicle with open 
windows i

Page 3431 of 4133

MERCEDES-BENZ ML320 1997  Complete Repair Manual Commercially available tools 
Workshop equipment 
DRAINING, EVACUATING AND REFILLING AIR CONDITIONING, CHECKING FUNCTION AND CHECKING FOR 
LEAKS - AR83.30-P-1760GH 
MODELS 163.113 /128 /136 /154 /157

Page 3432 of 4133

MERCEDES-BENZ ML320 1997  Complete Repair Manual Fig. 157: Checking Draining, Evacuating And Refilling Air Conditioning Function 
 Draining  
 
Risk of explosion from welding or 
soldering work on closed air conditioning 
system. Risk of poisoning .

Page 3433 of 4133

MERCEDES-BENZ ML320 1997  Complete Repair Manual  Air conditioning system 
Workshop equipment 
REMOVE/INSTALL DEFROSTER VENT FLAP ACTUATOR MOTOR FOR WINDSHIELD - AR83.30-P-2006GH 
MODEL 163.113 /154 /174 #A as of 289565, 163.113 #X as of 754620, 163

Page 3437 of 4133

MERCEDES-BENZ ML320 1997  Complete Repair Manual REMOVE/INSTALL FRESH AIR/RECIRCULATED AIR STEPPER MOTOR - AR83.30-P-2010GH 
MODEL 163.113 /128 /136 /154 /157 /172 /174 /175 with CODE (580) Air conditioning or Tempmatic for 
USA  
Shown on model 163

Page 3438 of 4133

MERCEDES-BENZ ML320 1997  Complete Repair Manual REMOVING AND INSTALLING BLENDING AIR INCREMENT ADJUSTMENT MOTOR - AR83.30-P-2020GH 
MODEL 163.113 /128 /136 /154 /157 /172 /174 /175 with CODE (580) Air conditioning or Tempmatic for 
USA  
Shown on m

Page 3439 of 4133

MERCEDES-BENZ ML320 1997  Complete Repair Manual REMOVE AND INSTALL EVAPORATOR HOUSING - AR83.30-P-5200GH 
MODELS 163.113 /128 /136 /154 /157 /172 /174 /175 with CODE (580) Air conditioning or Tempmatic for 
USA  
Fig. 163: Identifying Evaporator Ho

Page 3440 of 4133

MERCEDES-BENZ ML320 1997  Complete Repair Manual Fig. 164: Identifying Evaporator Housing Components (2 Of 2) 
 
 Remove/install  
 
Risk of explosion from welding or 
soldering work on closed air 
conditioning system. Risk of 
poisoning. Inhaling o