Page 23 of 37

24-93
Display fields
1 2 3 4
Display group 037: Diagnostic oxygen sensor control system
Display xxx %
x.xxx volts
xxx ms
---
Indicated Engine
load Oxygen sensor voltage
Bank 2, sensor 1 Dwell time, oxygen sensor control
before catalytic converter, bank 1 Diagnostic condition
Functional
range
Test OFF
Test ON
System OK
System not OK
Specified
value 15 to 33
% 0.100 to 0.900 V
-150 to 150 ms System OK
Note
If specified value is not
obtained: Evaluation display
field 2 Page 24
-94
If value climbs to above 300 ms,
this indicates a leaking exhaust
system or faulty oxygen sensor If "SYST not OK" is
displayed: Check DTC
memory Page 01
-16
Note for display field 3:
Oxygen sensor control behind catalytic converter is superior to oxygen sensor control before catalytic converter and is
responsible for control correction. It corrects slight changes in the mixture (i.e. toward rich or lean) due to the oxygen sensor
before catalytic converter by holding oxygen sensor control before catalytic converter at its higher or lower point for a specific
time (dwell time). If this time is in the positive range (i.e. 50 ms), mixture is shifted in the -enrich- direction. If this time is in the
negative range (i.e. -50 ms), mixture is shifted in the -lean- direction.
Pa
ge 23 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2
Page 24 of 37
24-94
Evaluation display group 037 Display field:
2
Possible cause
Corrective action
constant about
0.450 V
Open circuit in wire 4 between oxygen sensor
and control module - Check primary voltage Page 24
-96
Open circuit in wire 3 between oxygen sensor
and control module
larger than
1.100 V Short circuit to B+ in wire 4 between oxygen
sensor and control module - Check oxygen sensor wiring, oxygen sensor
behind catalytic converter Page 24
-97
smaller than
0.150 V
Short circuit to Ground (GND) in wire 4 between
oxygen sensor and control module
Pa
ge 24 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2
Page 25 of 37
24-95
Continuation
If specified value in display field 3 and 4 is not
obtained:
- Road test vehicle in order to free oxygen sensor
of possible residue and repeat test.
If specified value in display field 3 and 4 is not
obtained, even after road test:
- Replace Heated Oxygen Sensor (HO2S) -
G39-.
Note:
If oxygen sensor voltage is OK and dwell time of
oxygen sensor control behind catalytic converter
is still above 1200 ms, even after a road test, this
suggests aging of the oxygen sensor before
catalytic converter.
Pa
ge 25 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2
Page 32 of 37
24-102
- Start engine.
Specification: approx. battery voltage,
possibly fluctuating
Note:
At certain operating points, the ECM "pulses"
the Ground (GND) for oxygen sensor heating.
This means that the Ground (GND) is
constantly switched on and off at these points.
It is therefore possible that the voltage
displayed on the tester will fluctuate.
When the ECM switches oxygen sensor heating
on and off can be observed, if necessary, via
the function "read measuring value block"
display group number 041.
If there is no voltage:
- Connect multimeter for voltage measurement as
follows:
Harness connector
Terminal
Measure to
1 (B+) Vehicle Ground (GND)
Pa
ge 32 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2
Page: