24-162
Vacuum system, checking for leaks
- Let engine run 2 to 3 minutes at idle (for vacuum
to build up).
- Switch ignition off.
- Remove 2-pin connector from intake manifold
tuning valve -N156- (change-over valve).
- Connect jumper wire (from VAG1594) from one terminal of -N156- to
engine ground.
- Use VAG1248/3A remote, adapter wire VAG1348/3-2 and auxiliary
wire to connect second terminal of -N156- to B+.
- Activate intake manifold tuning valve -N156-, using remote control
VAG1348/3A, for approx. 2 to 3 min.
The vacuum solenoid must remain actuated during this time.
Pa
ge 10 of 11 Intake Manifold Tunin
g (IMT
) syste
m
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU03.24.3