24-96
- Switch Fluke 83 multimeter to voltage
measurement range and connect between
signal wire (trip computer 20-pin connector) and
Ground (GND), using wiring diagram.
- Start engine and let idle.
Specified value: approx. 0.3 to 0.6 volts,
corresponding to engine speed (RPM)
- Vary engine speed continuously from 1000 to
4000 RPM.
Specified value: approx. 0.3 to 0.6 volts,
corresponding to engine speed (RPM)
If the specified value is not obtained, even
though the trip computer shows no consumption
value or there is a stored malfunction in the
TCM:
- Stop engine (switch ignition off).
- Replace trip computer and/or TCM as
required.
If the specified value is not obtained:
Pa
ge 16 of 37 Auxiliar
y in
put si
gnals, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU01.24.25