01-27
VAG1551 scan tool
display Possible cause
Corrective action
00604
Back Pressure Flap
Motor Position Sensor
G113 in Air Flow Flap
Motor V71
Short circuit to
ground /SP
Open circuit/short
circuit to positive /SP
Adaptation limit
exceeded1)
Inoperative - Short circuit, open circuit in wiring or incorrect terminal
assignment (wires interchanged) of connectors between -
G113- and -E87-
- Air flow flap not operating freely
- -G113- in -V71- inoperative- Diagnose and repair short circuit,
open circuit in wiring or confirm
terminal assignment using wiring
diagram
- Check for free operation of air flow
flap2)
- Replace -V71-
00625
Road speed signal
Implausible signal /SP - Loose terminal in wiring/connections between
Speedometer Vehicle Speed Sensor (VSS) G22, the
instrument cluster or in another component also
connected to this signal (e.g. radio or control module for
cruise control) and -E87-
- Speedometer -G21- or instrument cluster supplying
unusable signal or a component disrupts signal - Diagnose and repair loose terminal
using wiring diagram.