Page 177 of 202

176
Check the battery for corroded or
loose terminal connections, cracks, or
loose hold-down clamp.
a. If the battery is corroded, wash it off
with a solution of warm water and baking
soda. Coat the outside of the terminals
with grease to prevent further corrosion.
b. If the terminal connections are loose,
tighten their clamp nutsÐbut do not over-
tighten.
c. Tighten the hold-down clamp only
enough to keep the battery firmly in place.
Overtightening may damage the battery
case.
NOTICE
Be sure the engine and all acces- sories are off before performing
maintenance.
When checking the battery, re-move the ground cable from the
negative terminal (к mark) firstand reinstall it last.
Be careful not to cause a short cir-cuit with tools.
Take care no solution gets into thebattery when washing it.
There are two types of batteries:
maintenance type and non-mainte-
nance type.
A non-maintenance battery has MAIN-
TENANCE FREE BATTERYº on its top. A
maintenance type battery does not have
such indication.
Maintenance type batteryÐ
Check the fluid condition by the fluid level
lines on the side of the battery. Or if the
battery has a hydrometer on its top, you
can also check the hydrometer.
Non-maintenance batteryÐ
Check the battery condition by the
hydrometer on the top of the battery.
ÐChecking battery exterior ÐChecking battery fluid
ProCarManuals.com
Page 178 of 202
177
CHECKING BY THE FLUID LEVEL
LINES (MAINTENANCE TYPE BAT-
TERY ONLY)
The fluid (electrolyte) level must be be-
tween the upper and lower lines.
When checking the fluid level, look at all
six cells, not just one or two.
If the level is lower than the lower line, add
distilled water. (See ADDING DIS-
TILLED WATERº.)CHECKING BY THE HYDROMETER
Check the battery condition by the
hydrometer color.
Maintenance type battery
Hydrometer colorConditionType AType BCondition
GREENBLUEGood
DARKWHITECharging necessary.
Have battery checked
by your Toyota dealer.
CLEAR orLIGHT
YELLOWREDAdd distilled water*
*: See ADDING DISTILLED WATERº. Non-maintenance battery
Hydrometer colorConditionType AType BCondition
GREENBLUEGood
DARKWHITECharging necessary.
Have battery checked
by your Toyota dealer.
CLEAR or
LIGHT
YELLOWREDHave battery checked
by your Toyota dealer.
NOTICE
Do not refill the battery with water.
ProCarManuals.com
Page 179 of 202

178
ADDING DISTILLED WATER (MAINTE-
NANCE TYPE BATTERY ONLY)
1. Remove the vent plugs.
2. Add distilled water to cells needing
fluid.
If the side of your battery is covered,
check the water level by looking down di-
rectly above the cell as illustrated above.
3. Retighten the vent plugs securely.
NOTICE
Do not overfill the cells. Excess electrolyte could squirt out of the
battery during heavy charging,causing corrosion or damage.
During recharging, the battery is pro-
ducing hydrogen gas.
Therefore, before recharging:
1. Maintenance type batteriesÐRemove
the vent plugs.
2. If recharging with the battery installed
on the vehicle, be sure to disconnect the
ground cable.
3. Be sure the power switch on the re-
charger is off when connecting the char-
ger cables to the battery and when dis-
connecting them.
Always charge the battery in an
unconfined area. Do not charge
the battery in a garage or closed
room where there is not sufficient
ventilation.
Non-maintenance batteries: Only
do a slow charge (5A or less).
Charging at a quicker rate is dan-
gerous. The battery may explode,
causing personal injuries.
Maintenance type batteries: Be
sure to remove the vent plugs be-
fore recharging. CAUTION
!
NOTICE
Never recharge the battery while the
engine is running. Also, be sure all
accessories are turned off.
Battery recharging precautions
ProCarManuals.com
Page 192 of 202

191
Oil grade:
API SH, Energy-Conserving IIº mul-
tigrade engine oil or ILSAC multi-
grade engine oil is recommended.
Recommended oil viscosity (SAE):
COOLING SYSTEM
Total capacity, L (qt., Imp. qt.): 9.3 (9.8, 8.2)
Coolant type: With ethylene-glycol antifreeze
(Do not use alcohol type.) BATTERY
ÐMaintenance type battery
Specific gravity reading at 20
5C (685 F)
1.260 Fully charged
1.160 Half charged
1.060 Discharged
ÐNon-maintenance type battery
Open voltage* at 205 C (685F)
12.7 V Fully charged
12.3 V Half charged
11.9 V Discharged
*: Voltage that is checked 20 minutes af-
ter the key is removed with all the lights
turned off
Charging Rates: Non-maintenance battery 5 A max.
Maintenance type battery
Quick charge 15 A max.
Slow charge 5 A max.
AUTOMATIC TRANSAXLE
Automatic transmission Fluid capacity (drain and refill),
L (qt., Imp. qt.):
Up to 3.5 (3.7, 3.1) Differential
Fluid capacity, L (qt., Imp. qt.):
0.85 (0.9, 0.7)
Fluid type: Automatic transmission fluid
DEXRON
[-II
BRAKES
Minimum pedal clearance when de-
pressed with the pressure of 490 N (50
kgf, 110 lbf) with the engine running, mm
(in.): 70 (2.8)
Pedal freeplay, mm (in.): 1' 6 (0.04' 0.24)
Pad wear limit, mm (in.): 1.0 (0.04)
Lining wear limit, mm (in.):
1.0 (0.04)
Parking brake adjustment when
depressed with the force of 294 N (30 kgf,
66.1 lbf):
3Ð6 clicks
Fluid type:
SAE J1703 or
FMVSS No. 116 DOT 3
STEERING
Wheel freeplay:
Less than 30 mm (1.2 in.)
Power steering fluid type:
Automatic transmission fluid
DEXRON
[-II or -III
ProCarManuals.com