12ENGINE
10
REPAIR 17.Slacken belt tensioner securing bolt to finger
tight.
18.Insert 13 mm square drive extension bar in
tensioner plate.
NOTE: Belt tensioning should be carried
out using a dial type torque meter having a
range not exceeding
60 Nm (44 lbf/ft).The
torque meter should be used in the almost vertical
position.
19.Apply a tension of
15 Nm (11 lbf/ft)for a new
belt or
12 Nm (9 lbf/ft)for an original belt. When
tension is correct, tighten clamp bolt.
20.Tighten injection pump gear bolts.
21.Remove pin from injection pump gear.
22.Disengage timing pin from timing slot in flywheel
or ring gear.
23.Rotate crankshaft one and three quarter turns in
a clockwise direction; then continue rotation until
timing pin in timing tool can be engaged with slot
in flywheel.
24.Disengage timing pin.
25.Insert pin from special toolLRT-12-045in
injection pump gear and through into pump
flange.
26.Slacken injection pump gear retaining bolts.
27.Slacken tensioner and retension belt.
28.Tighten injection pump gear retaining bolts.
29.Remove pin from injection pump gear.
30.Remove timing tool and refit plug.
31.Fit front cover plate using new gaskets.
See Front cover plate and seal
CRANKSHAFT GEAR
Service repair no - 12.65.25
Remove
1.Remove camshaft drive belt.
See Camshaft
drive belt
2.If the crankshaft gear cannot be removed by
hand, use special toolLRT-12-078with main
body and thrust button from special tool
LRT-12-031, as illustrated . Withdraw gear
complete with 'O' ring seal.
Refit
3.Lubricate new 'O' ring seal with petroleum jelly
and slide onto crankshaft, taking care not to
damage seal on woodruff keys.
4.Fit crankshaft gear and tap fully home ensuring
'O' ring seal is properly seated.
5.Fit camshaft drive belt.
See Camshaft drive
belt
19FUEL SYSTEM
2
DESCRIPTION AND OPERATION A mechanical lift pump, with a hand priming facility, is
driven by the camshaft, and is mounted on the RH
side of the engine.
A fuel filter, with a replaceable element and
incorporating a water separator, is mounted on the
front RH side of the engine compartment.
A fuel sedimentor may be fitted when the vehicle is
operating in more arduous conditions, and is used to
minimise water deposits in the fuel system before
reaching the fuel pump and filter.
Fuel injection is carried out by a Bosch direct injection
pump, incorporating a cold start advance unit and a
high idle setting. The pump is mounted on the RH side
of the engine and is driven directly by gears in the
front cover from the crankshaft. The pump meters and
distributes fuel to 4 pintle type injectors located in
pre-combustion chambers in the cylinder head. Four
heater plugs, located in the cylinder head directly
below each injector, are fitted to improve cold starting.
An optional hand throttle, for use with a centre power
take off, is located on the fascia to the LH side of the
fuse box, and is linked independently to the fuel
injection pump throttle lever.
Air intake
The air cleaner is mounted on the RH side of the
engine and is connected by hoses to the cold air
intake duct and turbocharger inlet. Fitted between the
air cleaner and turbocharger is the crankcase breather
hose which connects to a breather filter on the rocker
cover.
A single stage turbocharger, fitted between the
exhaust manifold and exhaust down pipe, is
connected by hoses to the air cleaner and an
intercooler which is mounted on the LH side of the
radiator. The intercooler is connected by a hose to the
inlet manifold. When an EGR valve is fitted to the
turbocharger, additional pipes/hoses are used to
connect the components.Exhaust gas recirculation (EGR), when fitted.
Exhaust gas recirculation is controlled by an ECU
mounted under the front centre seat or cubby box and
receives the following inputs:
·Engine temperature from coolant temperature
sender unit on LH side of cylinder head.
·Throttle position from potentiometer on injection
pump.
·Engine speed from speedometer.
When all correct signals are received, the EGR
solenoid allows vacuum to open EGR valve and
recirculate a portion of the exhaust gas. See J6196 for
the EGR system component location and 'Operation'
for full system function.
82AIR CONDITIONING
2
ADJUSTMENT SERVICING PRECAUTIONS
Care must be taken when handling refrigeration
system components. Units must not be lifted by their
hoses, pipes or capillary lines. Hoses and lines must
not be subjected to any twist or stress. Ensure that
hoses are positioned in their correct run before fully
tightening the couplings, and ensure that all clips and
supports are used. Torque wrenches of the correct
type must be used when tightening refrigerant
connections to the stated value. An additional spanner
must be used to hold the union to prevent twisting of
the pipe.
Before connecting any hose or pipe ensure that
refrigerant oil is applied to the seat of the new '0' ring
but not to the threads.
Check the oil trap for the amount of oil lost.
All protective plugs on components must be left in
place until immediately prior to connection.
The receiver/drier contains desiccant which absorbs
moisture. It must be positively sealed at all times.
CAUTION: Whenever the refrigerant
system is opened, the receiver/drier must
be renewed immediately before evacuating
and recharging the system.
Use alcohol and a clean cloth to clean dirty
connections.
Ensure that all new parts fitted are marked for use
withR134a.
Refrigerant oil
Use the approved refrigerant lubricating oil - Nippon
Denso ND-OIL 8.
CAUTION: Do not use any other type of
refrigerant oil.
Refrigerant oil easily absorbs water and must not be
stored for long periods. Do not pour unused oil back
into the container.
When renewing system components, add the
following quantities of refrigerant oil:
Condenser 40ml..........................................................
Evaporator 80ml..........................................................
Pipe or hose 20ml........................................................
Receiver/drier 20ml......................................................Total quantity of refrigerant oil in system = 140ml
A new compressor is sealed and pressurised with
Nitrogen gas, slowly release the sealing cap, gas
pressure should be heard to release as the seal is
broken.
NOTE: A new compressor should always
have its sealing caps in place and these
must not be removed until immediately
prior to fitting
A new compressor is supplied with an oil fill of 140ml.
A calculated quantity of oil must be drained from a
new compressor before fitting.
To calculate the quantity of oil to be drained:
1.Remove sealing plugs from the OLD
compressor.
2.Invert compressor and gravity drain oil into
measuring cylinder. Rotating the compressor
clutch plate will assist complete draining.
3.Note the quantity of oil drained (Yml).
4.Calculate the quantity (Qml) of oil to be drained
from the NEW compressor using the following
formula:
Xml - (Yml + 20ml) = Qml
Rapid refrigerant discharge
When the air conditioning system is involved in
accident damage and the circuit is punctured, the
refrigerant is discharged rapidly. The rapid discharge
of refrigerant will also result in the loss of most of the
oil from the system. The compressor must be
removed and all the remaining oil in the compressor
drained and refilled as follows:
1.Gravity drain all the oil, assist by rotating the
clutch plate (not the pulley).
2.Refill the compressor with 90ml of new
refrigerant oil.
3.Plug the inlet and outlet ports.
Servicing Equipment
The following equipment is required for full servicing
of the air conditioning system.
Recovery, recycling and charging station
Leak detector
Thermometer +20°C to -60°C
Safety goggles and gloves
AIR CONDITIONING
3
ADJUSTMENT REFRIGERANT RECOVERY, RECYCLING,
RECHARGING
WARNING: The air conditioning system is
charged with a high pressure, potentially
toxic refrigerant. Repairs or servicing must
only be carried out by an operator familiar with
both the vehicle system and the charging and
testing equipment.
All operations must be carried out in a
well-ventilated area away from open flame and
heat sources.
Always wear safety goggles and gloves when
opening refrigerant connections.
WARNING: Wear eye and hand safety
protection. Open connections slowly in
case liquid or pressure is present. Allow to
bleed off slowly.
CAUTION: Overcharging air conditioning
system will cause excessive head
pressure.
An air conditioning portable Refrigerant Recovery
Recycling Recharging Station for use with R134a
refrigerant incorporates all the features necessary to
recover refrigerant R134a from the air conditioning
system, to filter and remove moisture, to evacuate and
recharge with the reclaimed refrigerant. The unit can
also be used for performance testing and air
conditioning system analysis.
The operator must adhere to the equipment
manufacturers' instructions.
Recovery and recycling
1.Connect a Refrigerant Station to the high and
low pressure servicing connections.
2.Operate the refrigerant recovery system
according to the manufacturers instructions.
3.Measure the amount of oil discharged from the
system. Add an equal amount of new refrigerant
oil to compressor before evacuation sequence.
WARNING: Refrigerant must always be
recycled before reuse, to ensure that the
purity of the refrigerant is high enough for
safe use in the air conditioning system. Recycling
should always be carried out with equipment
which is design certified by Underwriter
Laboratory Inc. for compliance with SAE-J1991.
Other equipment may not recycle refrigerant to
the required level of purity.
A R134a Refrigerant Recovery Recycling
Recharging Station must not be used with any
other type of refrigerant.
Refrigerant R134a from domestic and commercial
sources must not be used in motor vehicle air
conditioning systems.
Evacuation and recharging
1.Add refrigerant oil to compressor if necessary.
2.Renew the receiver/drier.
CAUTION: When a major repair has been
carried out, a leak test should be carried
out using inert gas.
3.Connect a Refrigerant Station to the high and
low pressure servicing connections.
CAUTION: Whenever the refrigerant
system is opened, the receiver/drier must
be renewed immediately before evacuating
and recharging the system.
4.Operate the refrigerant evacuation system
according to the manufactures instructions.
NOTE: If the vacuum reading is below
700mmHg after 15 minutes, suspect a leak
in the system. Partially recharge the
system and check for leaks using an electronic
leak tester. Check suction lines first, then run the
compressor for 5 minutes and then check the high
pressure lines.
CAUTION: The system must be Evacuated
immediately before recharging
commences. Delay between Evacuation
and Recharging is not permitted.
82AIR CONDITIONING
4
ADJUSTMENT 5.Operate the refrigerant recharging system
according to the manufactures instructions.
Refrigerant to charge system is 1.1 kg.
6.If the full charge has not been accepted by the
system, start the engine and run it at 1500
rev/min for a minimum of 2 minutes.
Switch on the air conditioning system, open the
vehicle windows, set the temperature control to
cold and switch the blower to maximum speed.
7.Consult Refrigerant Station Manual for correct
procedure to complete the charge.
8.Carry out the air conditioning system
performance test.LEAK TEST SYSTEM
The following instructions refer to an electronic type
Refrigerant Leak Detector for use with R134a, which
is the safest and most sensitive.
CAUTION: When a major repair has been
carried out, a leak test should be carried
out using an inert gas (see below).
1.Place the vehicle in a well ventilated area but
free from draughts, as leakage from the system
could be dissipated without detection.
2.Follow the instructions issued by the
manufacturer of the particular leak detector
being used.
3.Commence searching for leaks by passing the
detector probe around all joints and components,
refrigerant gas is heavier than air.
4.Insert the probe into an air outlet of the
evaporator or into the evaporator drain tube.
Switch the air conditioning blower on and off at
intervals of ten seconds. Any leaking refrigerant
will be gathered in by the blower and detected.
5.Insert the probe between the magnetic clutch
and compressor to check the shaft seal for
leaks.
6.Check all service valve connections, valve plate,
head and base plate joints and back seal plate.
7.Check the condenser for leaks at the pipe
unions.
8.If any leaks are found, the system must be
discharged before rectification.
9.Rectify any leaks and recheck for leaks during
evacuation prior to charging.
Leak test using inert gas
Use Nitrogen or Helium gas.
1.Connect gas line to recharging station.
2.Pressurise system to 3 bar.
3.Carry out leak test as above.