Page 296 of 376
![FORD BRONCO 1996 5.G Owners Manual 299
*
[SV20151( ALL)01/95]
You may add water by itself only in an
emergency, but you should replace it with a
50/50 or appropriate mixture as soon as
possible.
*
[SV20200( ALL)01/95]
Have your dealer FORD BRONCO 1996 5.G Owners Manual 299
*
[SV20151( ALL)01/95]
You may add water by itself only in an
emergency, but you should replace it with a
50/50 or appropriate mixture as soon as
possible.
*
[SV20200( ALL)01/95]
Have your dealer](/manual-img/11/4755/w960_4755-295.png)
299
*
[SV20151( ALL)01/95]
You may add water by itself only in an
emergency, but you should replace it with a
50/50 or appropriate mixture as soon as
possible.
*
[SV20200( ALL)01/95]
Have your dealer check the engine cooling
system for leaks if you have to add a quart
(liter) of engine coolant more than once a month.
%*
[SV20500( ALL)11/94]
Checking hoses
*
[SV20600( ALL)10/89]
Inspect all engine and heater system hoses for
deterioration, leaks and loose clamps before
adding or replacing engine coolant. Make
whatever repairs or replacements that are
necessary using Motorcraft parts or their
equivalents.
*
[SV20700( ALL)05/95]
Engine coolant drain and flush
*
[SV20800( ALL)10/89]
To drain your vehicle's engine coolant:
*
[SV20900( ALL)03/94]
1. Turn off the engine and let it cool. Fully
depressurize the engine cooling system by
covering the radiator cap with a thick cloth
and turning it slowly counterclockwise to the
first stop. Step back while the pressure
releases.
*
[SV20950( ALL)05/90]
2. Remove the cap.
*
[SV21000(B FM)05/90]
3. Attach a small hose to the drain tube at the
bottom of the radiator.
*
[SV21200( ALL)05/90]
4. Let the engine coolant drain into a suitable
container. Disconnect the lower radiator hose
at the radiator connector and drain any
remaining engine coolant into a container.
*
[SV21225( ALL)05/94]
5. Reconnect the lower radiator hose and close
the radiator drain cock.
*
[SV21250( ALL)10/94]
Proper procedures for flushing the cooling
system can be found in theTruck Service Manual.
File:ltsvb.ex
Update:Tue Jun 20 16:56:22 1995
Page 297 of 376
![FORD BRONCO 1996 5.G Owners Manual 300
*
[SV21300( ALL)02/95]
Engine coolant refill procedure
*
[SV21400( ALL)10/89]
After you have drained the engine cooling
system:
*
[SV21500( ALL)01/89]
1. Fill the radiator with a 50/50 mixture of FORD BRONCO 1996 5.G Owners Manual 300
*
[SV21300( ALL)02/95]
Engine coolant refill procedure
*
[SV21400( ALL)10/89]
After you have drained the engine cooling
system:
*
[SV21500( ALL)01/89]
1. Fill the radiator with a 50/50 mixture of](/manual-img/11/4755/w960_4755-296.png)
300
*
[SV21300( ALL)02/95]
Engine coolant refill procedure
*
[SV21400( ALL)10/89]
After you have drained the engine cooling
system:
*
[SV21500( ALL)01/89]
1. Fill the radiator with a 50/50 mixture of the
specified engine coolant concentrate and
water. Allow several minutes for trapped air
to escape (bubble out) and for engine coolant
to flow through the radiator.
*
[SV21900( ALL)03/94]
2. Replace the radiator cap to its fully installed
position, then back off to the first stop. This
will prevent high pressure from building up
in the cooling system during this part of the
fill procedure.
*
[SV22100( ALL)10/89]
3. Start and idle the engine until the thermostat
opens and the radiator upper hose becomes
warm.
*
[SV22200( ALL)05/95]
4. Shut off the engine and allow the engine to
cool. Cover the radiator cap with a thick
cloth and cautiously remove it. Step back
while the pressure releases.
*
[SV22500( ALL)10/89]
5. Finally, check the radiator and add more
engine coolant if needed, following the
procedures noted above. Reinstall the
radiator cap securely, when finished.
*
[SV22525( ALL)05/90]
6. If more engine coolant is necessary, fill the
overflow reservoir to the appropriate level
marked on the bottle.
File:ltsvb.ex
Update:Tue Jun 20 16:56:22 1995
Page 349 of 376
![FORD BRONCO 1996 5.G Owners Manual 352 %
*
[SV57350( ALL)01/95]
Engine
*
[SV57400( ALL)01/95]
q
Start engine every 15 days. Run at fast idle
until it reaches normal operating temperature.
*
[SV57500( ALL)01/95]
q
With your foot on the FORD BRONCO 1996 5.G Owners Manual 352 %
*
[SV57350( ALL)01/95]
Engine
*
[SV57400( ALL)01/95]
q
Start engine every 15 days. Run at fast idle
until it reaches normal operating temperature.
*
[SV57500( ALL)01/95]
q
With your foot on the](/manual-img/11/4755/w960_4755-348.png)
352 %
*
[SV57350( ALL)01/95]
Engine
*
[SV57400( ALL)01/95]
q
Start engine every 15 days. Run at fast idle
until it reaches normal operating temperature.
*
[SV57500( ALL)01/95]
q
With your foot on the brake, shift through all
the gears while the engine is running.
%*
[SV57600( ALL)01/95]
Fuel system
*
[SV57700( ALL)07/94]
q
Fill fuel tank with high-quality unleaded fuel
until the first automatic shutoff of the fuel
pump nozzle.
*
[SV57900( ALL)03/95]
NOTE: During extended periods of vehicle
storage (60 days or more), fuel may
deteriorate due to oxidation. This can
damage rubber and other polymers in
the fuel system and may also clog
small orifices.
*
[SV58000( ALL)01/95]
Ford Gas Stabilizer should be added whenever
actual or expected storage periods exceed 60
days. Follow the instructions on the label. The
vehicle should then be operated at idle speed to
circulate the additive throughout the fuel system.
*
[SV58100( ALL)01/95]
A volatile corrosion inhibitor added to the fuel
system will protect the fuel system's inner
surfaces from corrosion. Follow the instructions
packaged with the product.
%*
[SV58200( ALL)01/95]
Cooling system
*
[SV58300( ALL)01/95]
q
Protect against freezing temperatures.
%*
[SV58400( ALL)01/95]
Battery
*
[SV58500( ALL)01/95]
q
Check and recharge as necessary.
*
[SV58600( ALL)01/95]
q
Keep connections clean and covered with a
light coat of grease.
%*
[SV58700( ALL)01/95]
Brakes
*
[SV58800( ALL)01/95]
q
Make sure brakes and parking brake are fully
released.
File:ltsvb.ex
Update:Tue Jun 20 16:56:22 1995