Page 21 of 64
01-262
Note:
The display group numbers can be selected in
sequence by pressing buttons <-1 and 3-> on the
VAG1551 scan tool, or the arrow buttons and
on the VAG1552 mobile scan tool or the arrow
buttons and on the screen of the VAS5051
tester.
- Press -C- button to input display group number
manually. Read measurin
g value block
Enter display group number XXX
Indicated on display:
- Press buttons -0-, -0- and -3-.
- Press -Q- button to confirm input.
Pa
ge 21 of 64 Basic settin
g (scan tool function 04
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.15
Page 22 of 64
01-263
Note:
For display group 3 (005):
To read the display fields for engine speed and
current engine torque with the engine running,
communication between the scan tool and the
control module must be terminated via the "End
Output" function page 01
-16
. Start the
engine and reinitiate communication between
the scan tool and the control module.
Rapid data transfer
Q
08 - Read measurin
g value block
Indicated on display:
- Press buttons -0- and -8- to select "Read measuring value block"
function 08.
- Press -Q- button to confirm input.
Read measurin
g value block
Enter display group number XXX
Indicated on display:
- Press buttons -0-, -0- and -3-.
- Press -Q- button to confirm input.
Pa
ge 22 of 64 Basic settin
g (scan tool function 04
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.15
Page 25 of 64
01-265
Note:
The display group numbers can be selected in
sequence by pressing buttons <-1 and 3-> on the
VAG1551 scan tool, or the arrow buttons and
on the VAG1552 mobile scan tool or the arrow
buttons and on the screen of the VAS5051
tester.
- Press -C- button to input display group number
manually. Read measurin
g value block
Enter display group number XXX
Indicated on display:
- Press buttons -0-, -0- and -4-.
- Press -Q- button to confirm input.
Pa
ge 25 of 64 Basic settin
g (scan tool function 04
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.15
Page 26 of 64
01-266
Note:
For test table display group 4:
Display group 4 is not occupied for control
modules with no. 4B0 907 389 without index
and cannot be selected for these control
modules by pressing buttons <-1 and 3-> on the
VAG1551 or by pressing the arrow buttons
and on the VAG1552 or via manual input.
If an attempt is made to select display group
number 4: Function is unknown or can not be performed at the moment.
Indicated on display:
-
Press button.
Rapid data transfer
HELP
Select function XX
Indicated on display:
Bypass display group number 4 or you will be forced to exit the "Read
measuring value block" function. Press the C-button to do this and then
select display group number 3 or 5 directly.
Pa
ge 26 of 64 Basic settin
g (scan tool function 04
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.15
Page 29 of 64
01-268
Note:
The display group numbers can be selected in
sequence by pressing buttons <-1 and 3-> on the
VAG1551 scan tool, or the arrow buttons and
on the VAG1552 mobile scan tool or the arrow
buttons and on the screen of the VAS5051
tester.
- Press -C- button to input display group number
manually. Read measurin
g value block
Enter display group number XXX
Indicated on display:
- Press buttons -0-, -0- and -5-.
- Press -Q- button to confirm input.
Pa
ge 29 of 64 Basic settin
g (scan tool function 04
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.15
Page 30 of 64
01-269
Note:
For display group 5 (005):
To read the display fields for yaw rate and
transverse acceleration while driving,
communication between the scan tool and the
control module must be terminated via the "End
Output" function page 01
-16
. Start the
engine and reinitiate communication between
the scan tool and the control module.
Rapid data transfer
Q
08 - Read measurin
g value block
Indicated on display:
- Press buttons -0- and -8- to select "Read measuring value block"
function 08.
- Press -Q- button to confirm input.
Read measurin
g value block
Enter display group number XXX
Indicated on display:
- Press buttons -0-, -0- and -5-.
- Press -Q- button to confirm input.
Pa
ge 30 of 64 Basic settin
g (scan tool function 04
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.15
Page 35 of 64
01-273
Note:
The display group numbers can be selected in
sequence by pressing buttons <-1 and 3-> on the
VAG1551 scan tool, or the arrow buttons and
on the VAG1552 mobile scan tool or the arrow
buttons and on the screen of the VAS5051
tester.
- Press -C- button to input display group number
manually. Read measurin
g value block
Enter display group number XXX
Indicated on display:
- Press buttons -0-, -0- and -6-.
- Press -Q- button to confirm input.
Pa
ge 35 of 64 Basic settin
g (scan tool function 04
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.15
Page 38 of 64
01-275
Note:
The display group numbers can be selected in
sequence by pressing buttons <-1 and 3-> on the
VAG1551 scan tool, or the arrow buttons and
on the VAG1552 mobile scan tool or the arrow
buttons and on the screen of the VAS5051
tester.
- Press -C- button to input display group number
manually. Read measurin
g value block
Enter display group number XXX
Indicated on display:
- Press buttons 1-, 2- and -5-.
- Press -Q- button to confirm input.
Pa
ge 38 of 64 Basic settin
g (scan tool function 04
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.15