Page 72 of 90
24-62
      
-  Connect multimeter to terminal 2 of connector 
and engine Ground (GND) for voltage 
measurement. 
     
-  Operate starter briefly.
     
   Specification: approx. battery voltage
     
Note:  
     Voltage is supplied to Mass Air Flow (MAF) 
sensor from Fuel Pump (FP) relay. 
      If there is no battery voltage.  
     
-  Check wire connection from terminal 2 of 
connector to Fuel Pump (FP) relay via fuse for 
open circuit and short circuit to Ground (GND), 
repair if necessary. 
     
       Electrical Wiring Diagrams, Troubleshooting & 
Component Locations   
Pa
ge 72 of 90 Motronic Multi
port Fuel In
jection 
(MFI
) system, servicin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.1 
     
        
        Page 75 of 90
24-65
      
Voltage supply for Mass Air Flow (MAF) 
sensor, checking (Bosch MAF sensor)  
    
Note:  
Voltage is supplied to Mass Air Flow (MAF) sensor from Fuel Pump (FP) 
relay. 
If there is no battery voltage.  
 Electrical Wiring Diagrams, Troubleshooting & Component Locations    -  Disconnect connector from Mass Air Flow (MAF) sensor.
-  Connect multimeter to terminal 2 of connector and engine Ground 
(GND) for voltage measurement. 
-  Operate starter briefly. 
   Specification: approx. battery voltage
-  Check wire connection from terminal 2 of connector to Fuel Pump (FP) 
relay via fuse for open circuit and short circuit to Ground (GND), repair 
if necessary. 
Pa
ge 75 of 90 Motronic Multi
port Fuel In
jection 
(MFI
) system, servicin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.1 
     
        
        Page 83 of 90
24-72
      
Checking voltage supply to Mass Air Flow 
(MAF) sensor  
     
-  Disconnect harness connector from air mass 
meter. 
    
Note:  
The mass air flow sensor receives its voltage supply via the fuel pump 
relay. 
If the reading does not match the battery voltage:  
 Electrical Wiring Diagrams, Troubleshooting & Component Locations    -  Connect hand-held multimeter (voltage measurement range) between 
engine Ground (GND) and socket 2 of connector. 
-  Operate starter briefly. 
   Specification: approx. battery voltage
-  Check for open circuit or short to Ground (GND) in wiring between fuel 
pump relay and socket 2 on connector via fuse. Repair if necessary. 
Pa
ge 83 of 90 Motronic Multi
port Fuel In
jection 
(MFI
) system, servicin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.1 
     
        
          
   
    
    Page:  