24-134
 
     
Evaporative Emission (EVAP) 
system, checking 
     
Evaporative Emission (EVAP) Canister 
Purge Regulator Valve -N80, checking
 
     
Checking for leaks  
      If there is no electrical signal (not activated) the 
solenoid valve remains closed.  
     
-  Disconnect hoses from Evaporative Emission 
(EVAP) Canister Purge Regulator Valve -N80. 
     
-  Start output Diagnostic Test Mode and select 
Evaporative Emission (EVAP) Canister Purge 
Regulator Valve -N80   Page 01
-75
 . 
Output Diagnostic Test Mode EVAP canister pur
ge re
gulator valve -N80
    
Indicated on display  
   The valve should click and should open and close (test by blowing into 
auxiliary hose). 
-  If valve does not click, carry out electrical test of Evaporative Emission 
(EVAP) Canister Purge Regulator Valve   Page 24
-135
 . 
-  If valve does not open and close properly, replace Evaporative 
Emission (EVAP) Canister Purge Regulator Valve. 
Pa
ge 1 of 6 Eva
porative Emission 
(EVAP
) system, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.3