DESCRIPTION AND OPERATION Condenser cooling fans
The condenser cooling fans operate automatically
whenever the air conditioning system is switched on.
Fan timer unit
The thermostatically controlled timer will continue to
operate the cooling fans after the air conditioning or
ignition is switched off. When the system temperature
is excessive, the fans will operate for 10 minutes to
reduce condenser and underbonnet temperature.
Blower control
The blower can be operated at any one of four speeds
by sliding the blower switch to the required position.
When the blower is switched off the air conditioning
system will not operate.
The fresh air/recirculation flaps can move between
two positions. One position covers the outside air
inlet, leaving open an inlet from the inside of the
vehicle clear, when recirculated air is required. In the
other position they will cover the inlet from the inside
of the vehicle leaving open the outside air inlet when
fresh air is required.Heater distribution and blend unit control
Blower unit air flow, having passed through the
evaporator passes into the heater blend unit to be
heated, if required. It is then directed into the vehicle
interior in accordance with the flap positions
designated by the air distribution control. Heater flaps
control the amount of air flowing through the heater
matrix. These flaps are controlled individually by the
driver's and passenger's temperature controls.
When the temperature control is in the cold position, a
micro switch actuates a vacuum control to close the
coolant valve on the engine. As the temperature
control is moved away from cold, the coolant valve is
opened allowing heated engine coolant to flow
throught the heater matrix. The temperature of the
heated air flow into the vehicle interior is controlled by
the blend flaps.
The distribution control moves the flaps which control
the direction of the air flow into the interior of the
vehicle.
82AIR CONDITIONING
2
FAULT DIAGNOSIS REFRIGERATION SYSTEM FAULTS
For any refrigeration system to function properly all
components must be in good working order. The unit
cooling cycle and the relationship between air
discharge temperature and ambient temperature and
the pressures at the compressor can help to
determine proper operation of the system.
The length of any cooling cycle is determined by such
factors as ambient temperature and humidity,
thermostat setting, compressor speed and air leakage
into the cooled area, etc. With these factors constant,
any sudden increase in the length of the cooling cycle
would be indicative of abnormal operation of the air
conditioner.
The low and high side pressures at the compressor
will vary with changing ambient temperature, humidity,
in-car temperature and altitude.
The following items should be checked before
operating the system:
1.Compressor drive belt tension.
2.Compressor magnetic clutch operation.
3.Condenser fan operation.
4.Condenser fins, dirt will cause poor cooling and
higher operating temperatures.The following conditions should be checked after
operating the system for several minutes:
1.All high pressure lines and components should
be hot to the touch.
2.All low pressure lines should be cool to the
touch.
3.Inlet and outlet temperatures at the receiver/drier
should be at the same temperature (warm). Any
very noticeable temperature difference indicates
a blocked receiver/drier.
4.Heavy frost on the inlet to the expansion valve
may indicate a defective valve or moisture in the
system.
5.Evaporation air temperature will vary with
ambient temperature and humidity. As humidity
increases the outlet temperature will be higher.
82AIR CONDITIONING
4
FAULT DIAGNOSISFAULT CAUSE REMEDY
E.
NOISY
EXPANSION
VALVE
(steady hissing)1. Low refrigerant charge; evident by
bubbles in sight glass.1. Leak test. Repair or replace
components as required.
F.1. Expansion valve not operating 1. Refer to C-2, C-3, D-1
INSUFFICIENTproperly. and E.
COOLING2. Low refrigerant charge-evident 2. Refer to B-1 and E.
by bubbles in sight glass.
3. Compressor not pumping. 3. Refer to B-2 and B-3
G.1. Belt tension. 1. Adjust belt tension.
COMPRESSOR2. Excessive head pressure. 2. Refer to A-1 through
BELTA-4 and C-6.
SLIPPING3. Incorrect alignment of pulleys 3. Repair as needed.
or worn belt not riding properly.
4. Nicked or broken pulley. 4. Replace as needed.
5. Seized compressor. 5. Replace compressor.
1. Loose or missing mounting bolts. 1. Repair as necessary.
2. Broken mounting bracket. 2. Replace bracket.
3. Loose flywheel or clutch 3. Repair as necessary.
retaining bolt.
H.4. Rough idler pulley bearing. 4. Replace bearing.
ENGINE5. Bent, loose, or improperly 5. Repair as necessary.
NOISEmounted engine drive pulley.
AND/OR6. Defective compressor bearing. 6. Replace bearing.
VIBRATION7. Insecure mountings of 7. Repair as necessary.
accessories; generator, power
steering, air filter, etc.
8. Excessive head pressure. 8. Refer to A-1, A-2, A-3
A-4 and C-6.
9. Incorrect compressor oil level. 9. Refer to compressor Oil
Level Check.
HEATER AND AIR CONDITIONING - CIRCUIT
DIAGRAMS
1.For details of heating and air conditioning
electrics
See Electrical Trouble Shooting
Manual.
82AIR CONDITIONING
6
ADJUSTMENT SYSTEM TEST
1.Place the vehicle in a ventilated, shaded area
free from excessive draught, with the doors and
windows open.
2.Check that the surface of the condenser is not
restricted with dirt, leaves, flies, etc. Do not
neglect to check the surface between the
condenser and the radiator. Clean as necessary.
3.Switch on the ignition and the air conditioner air
flow control. Check that the blower is operating
efficiently at low, medium and high speeds.
Switch off the blower and the ignition.
4.Check that the evaporator condensate drain
tubes are open and clear.
5.Check the tension of the compressor driving belt,
and adjust if necessary.
6.Inspect all connections for the presence of
refrigerant oil. If oil is evident, check for leaks,
and repair as necessary.
NOTE: The compressor oil is soluble in
Refrigerant R134a and is deposited when
the refrigerant evaporates from a leak.
7.Start the engine.
8.Set the temperature controls to cold and switch
the air conditioner blower control on and off
several times, checking that the magnetic clutch
on the compressor engages and releases each
time.9.With the temperature control at maximum
cooling and the blower control at high speed,
warm up the engine and fast idle at 1000
rev/min. Check the sight glass for bubbles or
foam. The sight glass should be generally clear
after five minutes running, occasional bubbles
being acceptable. Continuous bubbles may
appear in a serviceable system on a cool day, or
if there is insufficient air flow over the condenser
at a high ambient temperature.
10.Repeat at 1800 rev/min.
11.Gradually increase the engine speed to the high
range, and check the sight glass at intervals.
12.Check for frosting on the service valves.
13.Check the high pressure hoses and connections
by hand for varying temperature. Low
temperature indicates a restriction or blockage at
that point.
14.Switch off the air conditioning blower and stop
the engine.
15.If the air conditioning equipment is still not
satisfactory, carry out a pressure test as
previously described in this section.
COMPRESSOR DRIVE BELT
Service repair no - 82.10.01.
Tdi -
See ENGINE, Repair, Compressor drive belt
V8i and MpiSee ENGINE, Repair, Drive belt
82AIR CONDITIONING
6
REPAIR CONDENSER
Service repair no - 82.15.07
Remove
1.Disconnect battery negative lead.
WARNING: Wear eye and hand protection
when disconnecting components
containing refrigerant. Plug all exposed
connections immediately.
2.Recover refrigerant from system.
See
Adjustment, Refrigerant Recovery Recycling
Recharging
3.Remove front grille panel.
4.Remove battery.
See ELECTRICAL, Repair,
Battery
5.Remove radiator and oil coolers assembly.See
COOLING SYSTEM, Repair, Radiator
6.Disconnect high and low pressure pipes at
condenser unions.
7.Discard 'O' ring seal from each union.
8.Remove 2 bolts securing condenser to body.
9.Pull condenser into radiator area.
10.Disconnect multiplug from each fan lead.
11.Remove condenser assembly.
Do not carry out
further dismantling if component is removed
for access only.
Blank off inlet and outlet ports.
82AIR CONDITIONING
8
REPAIR HEATER AND COOLER UNIT
Service repair no - 86.25.21
WARNING: All work involving the service
and maintenance of air conditioning
requires special equipment, knowledge,
experience and a full awareness and adherence to
safety precautions.
Remove
1.Disconnect battery negative lead.
2.Drain engine coolant.
See COOLING SYSTEM,
Adjustment, Coolant
3.Recover refrigerant from air conditioning system.
See Adjustment, Refrigerant Recovery
Recycling Recharging
4.Remove fascia panel assembly.See CHASSIS
AND BODY, Repair, Dash Panel Assembly
5.Release clips and disconnect coolant hoses
from heater pipes.
6.Remove securing bolt and disconnect low
pressure pipe from evaporator.
WARNING: Wear eye and hand protection
when disconnecting components
containing refrigerant. Plug all exposed
connections immediately.
7.Release 'P' clip retaining high and low pressure
pipes.
8.Remove securing bolt and disconnect high
pressure pipe from evaporator.
9.Discard 'O' ring seals.
AIR CONDITIONING
13
REPAIR BLOWER MOTOR - REAR
Service repair no - 82.26.02
Remove
1.Remove evaporator/blower motor assembly.
See evaporator/blower motor assembly -
rear
2.Loosen 2 screws securing high pressure control
valve solenoid to blower motor housing.
3.Disconnect multiplug from blower motor.
4.Release blower motor cooling tube from
evaporator/blower motor housing.
5.Remove 3 screws securing blower motor.
6.Remove blower motor .
Refit
7.Position blower motor to housing and secure
with screws.
8.Secure blower motor cooling tube from
evaporator/blower motor housing.
9.Connect multiplug to blower motor.
10.Tighten screws securing control valve solenoid.
11.Fit evaporator/blower motor assembly.
See
evaporator/blower motor assembly - rear;
Refit
ELECTRONIC CONTROL UNIT - REAR AIR
CONDITIONING
Service repair no - 82.26.03
Remove
1.Remove rear compartment lower trim panel.
See CHASSIS AND BODY, Repair, rear
compartment lower trim panel - lh - with rear
air conditioning fitted
2.Disconnect multiplug from ECU.
3.Remove ECU from mounting bracket.
Refit
4.Fit ECU to mounting bracket and connect
multiplug.
5.Fit rear compartment lower trim panel.
See
CHASSIS AND BODY, Repair, rear
compartment lower trim panel - lh - with rear
air conditioning fitted; Refit
ELECTRICAL
41
REPAIR COOLANT TEMPERATURE TRANSMITTER - V8i
Service repair no - 26.10.02
Remove
1.Disconnect battery negative lead.
2.Disconnect lead from transmitter.
3.Remove transmitter, discard sealing washer if
fitted.
Refit
4.Coat threads of replacement transmitter with
Loctite 572.
5.Fit a new sealing washer to transmitter.
6.Fit transmitter, connect lead.
7.Top-up cooling system.HEATED FRONT SCREEN
Heated front screen will operate when switch is
operated, with engine running. Timer unit will provide
a preset time cycle of 7« minutes±20%.
To identify timer unit.
See Electrical Trouble
Shooting Manual.Electrical Troubleshooting
Manual
Switching OFF ignition, or further operation of heated
front screen switch during cycle will switch off screen
and cancel, reset and switch off timer unit.