01INTRODUCTION
8
INFORMATION TRANSPORTING THE VEHICLE BY TRAILER
Lashing eyes are provided on front and rear of the
chassis side members, to facilitate the securing of the
vehicle to a trailer or other means of transportation.
CAUTION: Underbody components must
not be used as lashing points.
Install vehicle on trailer and apply park brake. Select
neutral in main gearbox. Selecting 'N' will prevent
damage to parking pawl of the automatic gearbox.
FRONT OF CHASSIS
REAR OF CHASSIS
JUMP STARTING
WARNING: Hydrogen and oxygen gases
are produced during normal battery
operation. This gas mixture can explode if
flames, sparks or lighted tobacco are brought
near battery. When charging or using a battery in
an enclosed space, always provide ventilation and
shield your eyes.
Keep out of reach of children. Batteries contain
sulphuric acid. Avoid contact with skin, eyes, or
clothing. Also, shield eyes when working near
battery to protect against possible splashing of
acid solution. In case of acid contact with skin,
eyes, or clothing, flush immediately with water for
a minimum of fifteen minutes. If acid is swallowed,
drink large quantities of milk or water, followed by
milk of magnesia, a beaten egg, or vegetable oil.
SEEK MEDICAL AID IMMEDIATELY.
To Jump Start - Negative Ground Battery
WARNING: To avoid any possibility of
injury use particular care when connecting
a booster battery to a discharged battery.
1.Position vehicles so that jump leads will reach,
ensuring that vehiclesDO NOT TOUCH,
alternatively a fully charged slave battery may be
positioned on floor adjacent to vehicle.
2.Ensuring that ignition and all electrical
accessories are switched off, that parking brake
is applied and neutral is selected on a manual
gearbox, with an automatic gearbox select
neutral (N) or park (P) and then connect the
jump leads as follows;
A.Connect one end of first jumper cable to positive
(+) terminal of booster battery.
B.Connect other end of first jumper cable to
positive (+) terminal of discharged battery.
C.Connect one end of second jumper cable to
negative terminal of booster battery.
Tdi
3
REPAIR ENGINE
Service repair no - 12.41.01
Remove
CAUTION: Seal all exposed pipe ends
against ingress of dirt after disconnection.
1.Park vehicle on level ground and apply park
brake.
2.Disconnect battery negative lead.
3.Remove bonnet [hood].
See CHASSIS AND
BODY, Repair, Bonnet [Hood]
4.If air conditioning is fitted, remove RH footwell
side trim panel and disconnect harness multiplug
from relay.
5.Disconnect the two engine harness multiplugs
on LH side of footwell.
6.Remove engine harness grommet from
bulkhead and move harness into engine bay.
7.Release battery positive lead from retaining clip
at base of suspension turret.
8.Remove Radiator Assembly.
See COOLING
SYSTEM, Repair, Radiator
9.Discharge air conditioning system.See AIR
CONDITIONING, Adjustment, Refrigerant
Recovery Recycling Recharging
Remove retaining bolts and disconnect both pipe
adaptors from rear of compressor.
10.Remove rocker cover insulation.
11.Disconnect cyclone hose from air cleaner hose.
12.Remove air cleaner hose from turbocharger.
13.Remove feed pipe/hose from turbocharger and
intercooler.
14.Disconnect heater hoses from cylinder head and
heater rails.
15.Remove bolt securing transmission breather
pipe clip to cylinder head; move breather pipes
aside.
16.Disconnect inlet and outlet hoses from power
steering pump.
17.Disconnect bypass hose from thermostat
housing.
18.Release bypass hose from retaining clips on
front timing cover.
19.Remove split pin securing inner throttle cable to
injector pump.
20.Depress tags on outer cable adjusting nut,
remove cable from mounting bracket, and move
aside.
21.If automatic transmission is fitted, release
kickdown cable from injector pump and mounting
bracket.
AIR CONDITIONING
1
ADJUSTMENT GENERAL PRECAUTIONS
The refrigerant used in the air conditioning system is
HFC (Hydrofluorocarbon) R134a.
WARNING: R134a is a hazardous liquid
and when handled incorrectly can cause
serious injury. Suitable protective clothing
must be worn when carrying out servicing
operations on the air conditioning system.
WARNING: R134a is odourless and
colourless. Do not handle or discharge in
an enclosed area, or in any area where the
vapour or liquid can come in contact with naked
flame or hot metal. R134a is not flammable but
can form a highly toxic gas.
WARNING: Do not smoke or weld in areas
where R134a is in use. Inhalation of
concentrations of the vapour can cause
dizziness, disorientation. uncoordination,
narcosis, nausea or vomiting.
WARNING: Do not allow fluids other than
R134a or compressor lubricant to enter the
air conditioning system. Spontaneous
combustion may occur.
WARNING: R134a splashed on any part of
the body will cause immediate freezing of
that area. Also refrigerant cylinders and
replenishment trolleys when discharging will
freeze skin to them if contact is made.
WARNING: The refrigerant used in an air
conditioning system must be reclaimed in
accordance with the recommendations
given with a Refrigerant Recovery Recycling
Recharging Station.
NOTE: Suitable protective clothing
comprises: Wrap around safety glasses or
helmet, heatproof gloves, rubber apron or
waterproof overalls and rubber boots.REMEDIAL ACTIONS
1.If liquid R134a strikes the eye, do not rub it.
Gently run large quantities of eyewash over the
eye to raise the temperature. If eyewash is not
available cool, clean water may be used. Cover
eye with clean pad and seek immediate medical
attention.
2.If liquid R134a is splashed on the skin run large
quantities of water over the area as soon as
possible to raise the temperature. Carry out the
same actions if skin comes into contact with
discharging cylinders. Wrap affected parts in
blankets or similar material and seek immediate
medical attention.
3.If suspected of being overcome by inhalation of
R134a vapour seek fresh air. If unconscious
remove to fresh air. Apply artificial respiration
and/or oxygen and seek immediate medical
attention.
NOTE: Due to its low evaporating
temperature of -30°C, R134a should be
handled with care.
WARNING: Do not allow a refrigerant
container to be heated by a direct flame or
to be placed near any heating appliance. A
refrigerant container must not be heated above
50°C.
WARNING: Do not leave a container of
refrigerant without its cap fitted. Do not
transport a container of refrigerant that is
unrestrained, especially in the boot of a car.
82AIR CONDITIONING
2
ADJUSTMENT SERVICING PRECAUTIONS
Care must be taken when handling refrigeration
system components. Units must not be lifted by their
hoses, pipes or capillary lines. Hoses and lines must
not be subjected to any twist or stress. Ensure that
hoses are positioned in their correct run before fully
tightening the couplings, and ensure that all clips and
supports are used. Torque wrenches of the correct
type must be used when tightening refrigerant
connections to the stated value. An additional wrench
must be used to hold the union to prevent twisting of
the pipe.
Before connecting any hose or pipe ensure that
refrigerant oil is applied to the seat of the new '0' ring
but not to the threads.
Check the oil trap for the amount of oil lost.
All protective plugs on components must be left in
place until immediately prior to connection.
The receiver/drier contains desiccant which absorbs
moisture. It must be positively sealed at all times.
CAUTION: Whenever the refrigerant
system is opened, the receiver/drier must
be renewed immediately before evacuating
and recharging the system.
Use alcohol and a clean cloth to clean dirty
connections.
Ensure that all new parts fitted are marked for use
withR134a.
Refrigerant oil
Use the approved refrigerant lubricating oil:
Nippon Denso ND-OIL 8
Unipart R134a ND-OIL8
CAUTION: Do not use any other type of
refrigerant oil.
Refrigerant oil easily absorbs water and must not be
stored for long periods. Do not pour unused oil back
into the container.
When renewing system components, add the
following quantities of refrigerant oil:
Condenser 40ml..........................................................
Evaporator 80ml..........................................................
Pipe or hose 20ml........................................................
Receiver/drier 20ml......................................................
Total of refrigerant oil in system = 180ml = 6.3 Fl
ozA new compressor is sealed and pressurised with
Nitrogen gas, slowly release the sealing cap, gas
pressure should be heard to release as the seal is
broken.
NOTE: A new compressor should always
have its sealing caps in place and must
not be removed until immediately prior to
fitting
Fitting a new compressor
A new compressor is supplied with an oil fill (X) of:
180ml
A calculated quantity of oil must be drained from a
new compressor before fitting.
To calculate the quantity of oil to be drained:
1.Remove sealing plugs from the OLD compressor
2.Invert compressor and gravity drain oil into
measuring cylinder. Rotating the compressor
clutch plate will assist complete draining.
3.Note the quantity of oil drained (Y).
4.Calculate the quantity (Q) of oil to be drained
from the NEW compressor using the following
formula:
X - (Y + 20ml) = Q
Rapid refrigerant discharge
When the air conditioning system is involved in
accident damage and the circuit is punctured, the
refrigerant is discharged rapidly. The rapid discharged
of refrigerant will also result in the loss of most of the
oil from the system. The compressor must be
removed and all the remaining oil in the compressor
drained and refilled as follows:
1.Gravity drain all the oil, assist by rotating the
clutch plate (not the pulley).
2.Refill the compressor with the following amount
of new refrigerant oil:
130ml
3.Plug the inlet and outlet ports.
AIR CONDITIONING
3
ADJUSTMENT SERVICING EQUIPMENT
The following equipment is required for full servicing
of the air conditioning system.
Recovery, recycling and charging station
Leak detector
Thermometer +20°C to -60°C
Safety goggles and gloves
REFRIGERANT RECOVERY RECYCLING
RECHARGING
WARNING: The air conditioning system is
charged with a high pressure, potentially
toxic refrigerant. Repairs or servicing must
only be carried out by an operator familiar with
both the vehicle system and the charging and
testing equipment.
All operations must be carried out in a
well-ventilated area away from open flame and
heat sources.
Always wear safety goggles and gloves when
opening refrigerant connections.
WARNING: Wear eye and hand safety
protection. Open connections slowly in
case liquid or pressure is present. Allow to
bleed off slowly.
CAUTION: Overcharging air conditioning
system will cause excessive head
pressure.
An air conditioning portable Refrigerant Recovery
Recycling Recharging Station for use with R134a
refrigerant incorporates all the features necessary to
recover refrigerant R134a from the air conditioning
system, to filter and remove moisture, to evacuate and
recharge with the reclaimed refrigerant. The unit can
also be used for performance testing and air
conditioning system analysis.
The operator must adhere to the equipment
manufacturer's instructions.Recovery and recycling
1. High pressure servicing connection
2. Low pressure servicing connection
1.Connect a Refrigerant Station to the high and
low pressure servicing connections.
2.Operate the refrigerant recovery system
according to the manufacturer's instructions.
3.Measure the amount of oil discharged from the
system. Add an equal amount of new refrigerant
oil to compressor before evacuation sequence.
WARNING: Refrigerant must always be
recycled before reuse, to ensure that the
purity of the refrigerant is high enough for
safe use in the air conditioning system.
Recycling should always be carried out with
equipment which is design certified by
Underwriter Laboratory Inc. for compliance with
SAE-J1991. Other equipment may not recycle
refrigerant to the required level of purity.
A R134a Refrigerant Recovery Recycling
Recharging Station must not be used with any
other type of refrigerant.
Refrigerant R134a from domestic and commercial
sources must not be used in motor vehicle air
conditioning systems.
82AIR CONDITIONING
4
ADJUSTMENT Evacuation and recharging
1.Add refrigerant oil to compressor if necessary.
2.Renew the receiver/drier.
CAUTION: When a major repair has been
carried out, a leak test should be carried
out using inert gas.
3.Connect a Refrigerant Station to the high and
low pressure servicing connections.
CAUTION: Whenever the refrigerant
system is opened, the receiver/drier must
be renewed immediately before evacuating
and recharging the system.
4.Operate the refrigerant evacuation system
according to the manufacturer's instructions.
NOTE: If the vacuum reading is below
700mmHg after 15 minutes, suspect a leak
in the system. Partially recharge the
system and check for leaks using an electronic
leak tester. Check suction lines first, then run the
compressor for 5 minutes and then check the high
pressure lines.
CAUTION: The system must be evacuated
immediately before recharging
commences. Delay between evacuation
and recharging is not permitted.
5.Operate the refrigerant recharging system
according to the manufacturer's instructions:-
Refrigerant required to charge system:
Without rear air conditioning = 0.90kg (32 fl/oz)
With rear air conditioning = 1.15kg (40 fl/oz)
6.If the full charge has not been accepted by the
system, start the engine and run it at 1500
rev/min for a minimum of 2 minutes.
Switch on the air conditioning system, open the
car windows, set the temperature control to cold
and switch the blower to maximum speed.
7.Consult Refrigerant Station Manual for correct
procedure to complete the charge.
8.Carry out the air conditioning system
performance test.LEAK TEST SYSTEM
The following instructions refer to an electronic type
Refrigerant Leak Detector for use with R134a, which
are the safest and most sensitive.
CAUTION: When a major repair has been
carried out, a leak test should be carried
out using an inert gas (see below).
1.Place the vehicle in a well ventilated area but
free from draughts, as leakage from the system
could be dissipated without detection.
2.Follow the instructions issued by the
manufacturer of the particular leak detector
being used.
3.Commence searching for leaks by passing the
detector probe around all joints and components,
refrigerant gas is heavier than air.
4.Insert the probe into an air outlet of the
evaporator or into the evaporator drain tube.
Switch the air conditioning blower on and off at
intervals of ten seconds. Any leaking refrigerant
will be gathered in by the blower and detected.
5.Insert the probe between the magnetic clutch
and compressor to check the shaft seal for
leaks.
6.Check all service valve connections, valve plate,
head and base plate joints and back seal plate.
7.Check the condenser for leaks at the pipe
unions.
8.If any leaks are found, the system must be
discharged before rectification.
9.Rectify any leaks and recheck for leaks during
evacuation prior to charging.
Leak test using inert gas
Use Nitrogen or Helium gas.
1.Connect gas line to recharging station.
2.Pressurise system to 3 bar.
3.Carry out leak test as above.
82AIR CONDITIONING
2
REPAIR PERIODIC MAINTENANCE
Routine servicing, apart from visual checks, is not
necessary. The visual inspections are as follows:
Condenser
With a water hose or air line, clean the fins of the
condenser to remove flies, leaves, etc. Check the pipe
connections for signs of oil leakage.
Compressor
Check pipe connections for signs of oil leakage.
Check flexible hoses for swelling. Examine the
compressor belt for tightness and condition.
Sight glass and Receiver/Drier
Examine the sight glass for bubbles with the system
operating. Check connections for leakage.
Evaporator
Examine the refrigeration connections at the unit. If
the system should develop a fault, or if erratic
operation is noticed,
See Fault diagnosis,
Refrigeration System Faults
RECEIVER DRIER
Service repair no - 82.17.01
Remove
CAUTION: If receiver/drier is to be refitted,
the ports must be blanked off immediately
on disconnection. Exposed life of unit is
only 15 minutes.
1.Disconnect battery negative lead.
2.Recover refrigerant from system.
See
Adjustment, Refrigerant Recovery Recycling
Recharging
WARNING: Wear eye and hand protection
when disconnecting components
containing refrigerant. Plug all exposed
connections immediately.
3.Remove 3 screws from bonnet locking platform
and remove radiator grille.
Automatic gearbox
4.Remove 4 bolts securing transmission oil cooler
to body.
AIR CONDITIONING
3
REPAIR 5.Disconnect 2 pipe unions from oil cooler. Use a
second wrench to support hose adapter.
6.Remove transmission oil cooler. Seal
connections.
All models
7.Remove bolt securing receiver/drier clamp.
WARNING: Wear eye and hand protection
when disconnecting components
containing refrigerant. Plug all exposed
connections immediately.
8.Move receiver/drier just sufficiently to gain
access to pipe flange bolts without distorting the
pipes.
9.Remove bolt securing each pipe flange to
receiver/drier.
10.Disengage pipe flanges and withdraw
receiver/drier from mounting bracket.
11.Remove 'O' ring from each pipe flange.Refit
12.Fit new 'O' ring to each pipe flange, lubricate
with refrigerant oil.
13.Position receiver/drier in mounting bracket with
inlet and outlet connections correctly aligned.
14.Engage pipe flanges, fit bolts in turn and tighten.
15.Fit clamp bolt.
Automatic gearbox
16.Refit transmission oil cooler. Use a second
wrench to support pipe unions.
17.Check gearbox fluid level, top-up if necessary.
All models
18.Evacuate and recharge air conditioning system.
See Adjustment, Refrigerant Recovery
Recycling Recharging
19.Perform a leak test on disturbed joints.
20.Carry out a functional check.