Page 29 of 46
24-97
Display on VAS5051:
1 - Enter display group Max. input value = 255
- Select function "030" in button field -2- for "display group number 030"
and press Q button to confirm input.
Display on VAS5051:
Note:
"Oxygen sensor status" indicates status of oxygen sensor control and
oxygen sensors. - Check specified value in display field -2-.
Pa
ge 29 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2
Page 30 of 46
24-98
Display fields
1 2 3 4
Display group 030: Oxygen sensor status
Display X X X
X X X
Indicated Oxygen sensor status, bank 1, sensor 1
Oxygen sensor status bank 2, sensor 1
Functional range 0 = off
1 = on 0 = off
1 = on
Specified value 1 1 1
1 1 0
Note
If specified value is not obtained Page 24
-107
Significance of 3 digit indications in display group 030 X
X
X
Display fields 1 and 2
X Oxygen sensor control: 0= not active; 1 = active
X Operational readiness of oxygen sensor: 0= not active; 1 = active
X Condition of oxygen sensor heater: 0= not active; 1 = active
Notes:
The first position of the 3 digit indication (heating) fluctuates between 0 and 1.
Oxygen sensor control of oxygen sensor after catalytic converter (B1-S2) is not active without engine load.
Pa
ge 30 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2
Page 31 of 46
24-99
Display on VAS5051:
Checking oxygen sensor control after catalytic converter
Test requirement: - Do not continue test until indication in display field -2- has reached
"110" at least once.
Engine continues to run at 2600 RPM.
-
Click on - button
Display on VAS5051:
1 - Enter display group Max. input value = 255
- Select function "037" in button field -2- for "display group number 037"
and press -Q- button to confirm input.
Pa
ge 31 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2
Page 32 of 46
24-100
Display on VAS5051:
- Check oxygen sensor voltage in display field -2-.
- Check oxygen sensor correction value in display field -3- and
diagnostic result in display field -4-.
Pa
ge 32 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2
Page 33 of 46
24-101
Display fields
1 2 3 4
Display group 037: Diagnostic oxygen sensor control system
Display xxx %
x.xxx V
x.xx
---
Indicated Engine
load Oxygen sensor voltage
Bank 2, sensor 1 Oxygen sensor correction value
between bank 1, sensor 1 and
bank 1, sensor 2 Diagnostic condition
Functional
range
Test OFF
Test ON
System OK
System not OK
Specified
value 13 to 40
% 0.100 to 0.950 volts
smaller than 0.02 System OK
Note
If specified value is not
obtained: Evaluation
Page 24
-102
If "System not OK" is
displayed: Check DTC
memory Page 01
-12
Note for display field 2:
Oxygen sensor voltage bank 1, sensor 2 should remain fairly constant. Strong voltage fluctuations point to a damaged
catalytic converter.
Pa
ge 33 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2
Page 34 of 46
24-102
Evaluation display group 037 Display field: 2
Possible cause
Corrective action
constant about
0.450 V
Open circuit in wire 4 between oxygen sensor
and control module - Check primary voltage Page 24
-104
Open circuit in wire 3 between oxygen sensor
and control module
larger than
0.950 V Short circuit to B+ in wire 4 between oxygen
sensor and control module - Check oxygen sensor wiring, oxygen sensor after
catalytic converter Page 24
-105
smaller than
0.100 V
Short circuit to Ground (GND) in wire 4 between
oxygen sensor and control module
Pa
ge 34 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2
Page 35 of 46
24-103
Continuation
If specified value in display field 3 and 4 is not
obtained:
- Road test vehicle in order to free oxygen sensor
of possible residue and repeat test.
If specified value in display field 3 and 4 is not
obtained, even after road test:
- Replace Heated Oxygen Sensor (HO2S) -
G39-.
Note:
If oxygen sensor voltage is OK and oxygen
sensor correction value is still above 0.02 ms,
even after a road test, this suggests aging of an
oxygen sensor before catalytic converter.
Pa
ge 35 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2
Page 42 of 46
24-109
If specified value is obtained:
- Check voltage supply of oxygen sensor
heating.
Checking voltage supply for oxygen sensor
heating
Note:
When the Engine Control Module (ECM) switches oxygen sensor heating
on and off, it may be observed via the function "read measuring value
block", in display group number 041 display field 4.
If there is no voltage: - Connect multimeter between terminal 1 (B+) and 2 (Ground -GND-) for
voltage measurement.
- Start engine.
Specification: approx. battery voltage
- Connect multimeter for voltage measurement as follows:Harness connector
Terminal
Measure to
1 (B+) Vehicle Ground (GND)
Pa
ge 42 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2
Page: