1994 MITSUBISHI 3000GT check engine

[x] Cancel search: check engine

Page 474 of 738

MITSUBISHI 3000GT 1994 2.G Workshop Manual Downloaded from www.Manualslib.com manuals search engine 16-28ENGINE ELECTRICAL - Starting System
Stop ringZ6EL0097
Z6ELOO96+B,SNAP
 RING / STOP RING REMOVAL
(1) Press the stop ring, by using an appro

Page 475 of 738

MITSUBISHI 3000GT 1994 2.G Workshop Manual Downloaded from www.Manualslib.com manuals search engine ENGINE ELECTRICAL - Starting System16-29
ZiELllS
UndercutI
(2) Check the outer diameter of the commutator.
Standard value: 29.4 mm (1.158 in.)

Page 476 of 738

MITSUBISHI 3000GT 1994 2.G Workshop Manual Downloaded from www.Manualslib.com manuals search engine 16-30ENGINE ELECTRICAL - Starting System
Eq
C-- Wear limit line
-
New brush
Soldered
(Make sure that
there is no
excess solder on
brush surface

Page 477 of 738

MITSUBISHI 3000GT 1994 2.G Workshop Manual Downloaded from www.Manualslib.com manuals search engine i/ENGINE ELECTRICAL 
- Ignition System
IGNITION SYSTEM
16-31
SPECIFICATIONSGENERAL SPECIFICATIONS
CRANK ANGLE SENSOR cup to 1992 model>
Items
S

Page 481 of 738

MITSUBISHI 3000GT 1994 2.G Workshop Manual Downloaded from www.Manualslib.com manuals search engine i;ENGINE ELECTRICAL 
- Ignition System16-35
OPERATIONl
Turn ignition switch to .“ON”position, and batteryvoltage will be applied to primary

Page 482 of 738

MITSUBISHI 3000GT 1994 2.G Workshop Manual Downloaded from www.Manualslib.com manuals search engine 16-36ENGINE ELECTRICAL - Ignition System
Defective insulation
Defective insulation’
GoodZiELO34
ON-VEHICLE SERVICESPARK PLUG CABLE TEST
,d
(1

Page 483 of 738

MITSUBISHI 3000GT 1994 2.G Workshop Manual Downloaded from www.Manualslib.com manuals search engine /
LiENGINE ELECTRICAL 
- lanition Svstem16-37
--7EL0134IGNITION SECONDARY VOLTAGE WAVE-FORM
CHECK
MEASUREMENT METHOD
(1) Clamp SECONDARY PICKUP

Page 487 of 738

MITSUBISHI 3000GT 1994 2.G Workshop Manual Downloaded from www.Manualslib.com manuals search engine ENGINE ELECTRICAL - lanition Svstem16-41
/
L
i
Analyzer
GroundL
01L1008
STANDARD WAVE-FORM
Observation ConditionsIGNITION PRIMARY VOLTAGE WAVE-