MAZDA MX-5 1994  Workshop Manual DECHOKE CONTROL SYSTEM DECHOKE CONTROL SYSTEM DESCRIPTION To clean out excess fuel in cylinders, as in the case of engine flooding, when the engine is cold, no fuel will be injected when the accelerat

Page 287 of 1708

MAZDA MX-5 1994  Workshop Manual COOLANT FAN CONTROL COOLANT FAN CONTROL OUTLINE The PCME controls the coolant fan and the condenser fan to provide more efficient fan control. This 4 improves the performance reliability and stability

Page 288 of 1708

MAZDA MX-5 1994  Workshop Manual COOLANT FAN CONTROL F COOLANT FAN The coolant fan rotates at a constant velocity. L / Operation Condition TEN TERMINAL (DATA LINK CONNECTOR) IDLE SWITCH ----- OFF EXCEPT AT STARTING I ENGINE COOLAN

Page 289 of 1708

MAZDA MX-5 1994  Workshop Manual COOLANT FAN CONTROL SYSTEM INSPECTION 1. Connect the SST to the data link connector. 2. Set switch @ to position 1. 3. Set the test switch to SELF-TEST. 4. Turn the ignition switch ON. 5. Rotate the t

Page 291 of 1708

MAZDA MX-5 1994  Workshop Manual CONTROL SYSTEM STRUCTURAL VIEW i 1. Powertrain control module (engine) 6. Heated oxygen sensor Inspection . . . . . . . . . . . . . . . . . . page F-144 Inspection . . . . . . . . . . . . . . . . . .

Page 294 of 1708

MAZDA MX-5 1994  Workshop Manual CONTROL SYSTEM F Terminal voltage B+: Battery positive voltage Test condition I Voltage I Remark - - - - - - - - - - - - - - - - - - Connection to Battery Constant Ignition switch OFF Main relay - B+

Page 295 of 1708

MAZDA MX-5 1994  Workshop Manual F CONTROL SYSTEM B+: Battery positive voltage Connection to 1 Test condition 1 Voltage I Remark I -- EGR solenoid valvi Idle B+ Blower switch -- EGR solenoid valve (vacuum) :vent) Initial acceleration

Page 296 of 1708

MAZDA MX-5 1994  Workshop Manual CONTROL SYSTEM F Connection to I Test condition I Hot condition: Enaine coolant Input - temp. above 70°C (1 58"~) and in- PRC solenoid valve take air temp. above 50°C (122°F) for 150 sec. after ena