DIAGNOSTIC CODE CHART
If a malfunction code is displayed during the diagnostic code check (sens\
or check), check the circuit listed for
that code in the table below (Proceed to the page given for that circuit.)\
Code No.Diag. Code Detecting Condition
00 Normal
11 *1 Open or short in room temperature sensor circuit.
12 Open or short in ambient temperature sensor circuit.
13 Open or short in evaporator temperature sensor circuit.
14*2 Open or short in water temperature sensor circuit.
21*3 Open in solar sensor circuit.
21*3
Short in solar sensor circuit.
22*4
All conditions below are detected for 3 secs. or more.
(a) Engine rpm : 450 rpm or more.
(b) Ratio between engine and compressor rpm deviates 20% or more in c\
omparison to normal
operation.
23
Open in pressure sensor circuit.
Abnormal refrigerant pressure below 206 kPa (2.1 kgf/cm, 30 psi)
over 2,650 kPa (27 kgf/cm, 385 ps\
i)
31 Short to ground or power source circuit in Air Mix Damper position sens\
or circuit.
32 Short to ground or power source circuit in Air Inlet Damper position se\
nsor circuit.
33 Short to ground or power source circuit in Air Outlet Damper position s\
ensor circuit.
41 Air mix damper position sensor value does not change even if ECU operat\
es air mix servomotor.
42 Air inlet damper position sensor value does not change even if ECU oper\
ates air inlet servomotor.
43 Air outlet damper position sensor value does not change even if ECU ope\
rates air outlet
servomotor.
HINT: *1 If the room temp. is approx. ±20 °C (±4 °F) or lower, code 11 may be output even though the system
is normal.
*2 If the ambient temperature is approx. ±50 °C (±58 °F) or lower, a malfunction code may be output
even though the system is normal.
*3 If the check is being performed in a dark place, diagnostic code 21 (so\
lar sensor circuit abnormal) could be displayed.
In this case, perform diagnostic code check again while shining a light,\
such as an inspection light,
on the solar sensor.
If code 21 is still displayed, there could be trouble in the solar senso\
r circuit
AC±28
±
AIR CONDITIONING SYSTEM Troubleshooting
WhereEverybodyKnowsYourName
Trouble AreaMemory*5See page
±±±
Room temp. Sensor
Harness or connector between room temp. sensor and A/C control assembly\
A/C control assemblyO
(8.5 min. or more)AC±44
Ambient temp. sensor
Harness or connector between ambient temp. sensor and A/C control assem\
bly
A/C control assemblyO
(8.5 min. or more)AC±46
Evaporator temp. sensor
Harness or connector between evaporator temp. sensor and A/C control
assembly A/C control assemblyO
(8.5 min. or more)AC±48
Water temp. sensor
Harness or connector between water temp. sensor and A/C control assembl\
y
A/C control assemblyO
(8.5 min. or more)AC±50
Solar sensor
H b d A/C l bl
±
AC 52 Solar sensor
Harness or connector between sensor and A/C control assembly
A/C control assemblyOAC±52
A/C control assemblyO
(8.5 min. or more)
Compressor drive belt Compressor lock sensor Compressor
Harness and connector between A/C control assembly and compressor,
compressor lock sensor
A/C control assembly
±AC±54
Pressure switch
Harness or connector between pressure switch and A/C control assembly
Refrigerant pipe line
A/C control assembly
±AC±56
Air mix damper position sensor A/C control assembly
Harness or connector between air mix damper position sensor and
A/C control assemblyO
(1 min. or more)AC±58
Air inlet damper position sensor A/C control assembly
Harness or connector between air inlet damper position sensor and
A/C control assemblyO
(1 min. or more)AC±62
Air outlet damper position sensor A/C control assembly
Harness or connector between air outlet damper position sensor and
A/C control assemblyO
(1 min. or more)AC±66
Air mix servomotor Air mix damper position sensor
Harness and connector between A/C control assembly and air mix position\
sensor
Harness and connector between A/C control assembly and air mix servomot\
or.O
(15 secs. or more)AC±58
AC±60
Air inlet servomotor Air inlet damper position sensor
Harness and connector between A/C control assembly and air inlet positi\
on sensor.
Harness and connector between A/C control assembly and air inlet servom\
otor.O
(15 secs. or more)AC±62
AC±64
Air outlet servomotor Air outlet damper position sensor
Harness and connector between A/C control assembly and air outlet posit\
ion
sensor.
Harness and connector between A/C control assembly and air outlet servo\
motor.
A/C control assembly
O
(15 secs. or more)AC±66
AC±68
±
AIR CONDITIONING SYSTEM TroubleshootingAC±29
WhereEverybodyKnowsYourName
AC±44AC±46AC±48AC±50AC±52AC±54AC±56AC±58AC±60AC±62AC±64AC±66
MATRIX CHART OF PROBLEM SYMPTOMS
If a normal code is displayed during the diagnostic code check (sensor ch\
eck) but the trouble still occurs (reap-
pears), perform out troubleshooting for each problem symptom, checking the circuits for each symptom in the
order given in the table below (Proceed to the page given for each circuit)\
. AC±36
±
AIR CONDITIONING SYSTEM Troubleshooting
WhereEverybodyKnowsYourName
Check voltage between terminals TR
and SG of air conditioner assembly
connector.
Check room temperature sensor.
Check harness and connector between air
conditioner control assembly and room tem-
perature sensor (See page IN-27).
Check and repair air conditioner control
assembly. Proceed to next circuit inspection
shown on matrix chart (See page
AC-36
).However, when Diag. code
11 is displayed, check and replace
air conditioner control assembly.
Replace room temperature sensor.
Repair or replace harness or
connector.
CIRCUIT INSPECTION
Diag. Code 11Room Temperature Sensor Circuit
CIRCUIT DESCRIPTION
This sensor detects the temperature inside the cabin and sends the appropria\
te signals the A/C control
assembly.
Code No.Diag. Code Detecting ConditionTrouble area
11
Open or short in room temperature sensor
circuit. Room temperature sensor.
Harness or connector between room temp.
sensor and A/C control assembly.
A/C control assembly.
DIAGNOSTIC CHART
AC±44±
AIR CONDITIONING SYSTEM Troubleshooting
WhereEverybodyKnowsYourName
Check voltage between terminals TR and SG of air conditioner control
assembly connector.
(1) Remove console upper panel. (See page BO-111 )
(2) Remove A/C Control Assembly with connectors
still connected.
(3) Turn ignition switch ON.
Check voltage between terminals TAM and SG of air
conditioner control assembly connector at each tem-
perature.
Voltage
at 25°C (77°F) : 1.8~2.2 V
at 40°C (104°F) : 1.2~1.6 V
In addition, as the temperature increases, the
voltage decreases gradually.
Proceed to next circuit inspection shown on
matrix chart (See page AC-36).However,
when Diag. code 11 is displayed, check and
replace air conditioner control assembly.
Check room temperature sensor.
(1) Remove instrument finish lower No. 1 panel.
(See page Be-103).
Resistance
at 25°C (77°F) : 1.6~1.8k
at 50°C (122°F) : 0.5~0.7k
In addition, as the temperature increases, the
voltage decreases gradually.
Replace room temperature sensor.
Check for open and short in harness and connector between air conditioner
control assembly and room temperature sensor (See page IN-27).
Repair or replace harness or connector.
Check and repair air conditioner control
assembly.
(2) Disconnect room0 temperature sensor
connector.
Check voltage between terminals 1 and 2 of
room temperature sensor connector at each tem±
perature.
INSPECTION PROCEDURE
±
AIR CONDITIONING SYSTEM TroubleshootingAC±45
WhereEverybodyKnowsYourName
Diag. Code 12Ambient Temperature Sensor Circuit
CIRCUIT DESCRIPTION
This sensor detects the ambient temperature and sends the appropriate signal\
s to the A/C control
assembly.
Code No.Diag. Code Detecting ConditionTrouble area
12
Open or short in ambient temperature sensor
circuit.Ambient temperature sensor.
Harness or connector between ambient
temperature sensor and A/C control assem-
bly.
A/C control assembly.
DIAGNOSTIC CHART
Check voltage between terminals TAM and
SG of air conditioner control assembly con-
nector.
Check ambient temperature sensor.
Check harness and connector between air
conditioner control assembly and ambient
temperature sensor. (See page IN-27).
Check and replace air conditioner control
assembly.
Proceed to next circuit inspection
shown on matrix chart (See
pageAC-36 ). However, when Diag.
code 12 is displayed, check and re-
place air conditioner control assembly.
Replace ambient temperature
sensor.
Repair or replace harness or
connector.
AC±46±
AIR CONDITIONING SYSTEM Troubleshooting
WhereEverybodyKnowsYourName
Check voltage between terminals TAM and SG of air conditioner
control assembly connector.
(1) Remove console upper panel. (See page BO-111
(2) Remove A/C control assembly with
connectors still connected.
(3) Turn ignition switch ON.
Check voltage between terminals TAM and SG of air
conditioner control assembly connector at each tem-
perature.
at 25°C (77°F) : 1.35~1.75 V
at 40°C (104°F) : 0.85~1.25 V
In addition, as the temperature increases, the
voltage decreases gradually.
Proceed to next circuit inspection shown on
matrix chart (See page AC-36).However,
when Diag. code 11 is displayed, check and
replace air conditioner control assembly.
Check ambient temperature sensor.
(1) Remove under cover
(2) disconnect ambient temperature sensor connector.
Check resistance between terminals 1 and 2 of
ambient temperature sensor connector at each
temperature.
Resistance
at 25°C (77°F) : 1.6~1.8k
at 50°C (122°F) : 0.5~0.7k
In addition, as the temperature increases, the
voltage decreases gradually.
Replace ambient temperature sensor.
Check for open and short in harness and connector between air conditioner
control assembly and ambient temperature sensor (See page IN-27).
Repair or replace harness or connector.
Check and repair air conditioner control
assembly.
Voltage
INSPECTION PROCEDURE
±
AIR CONDITIONING SYSTEM TroubleshootingAC±47
WhereEverybodyKnowsYourName
Diag. Code 13Evaporator Temperature Sensor Circuit
CIRCUIT DESCRIPTION
This sensor detects the temperature inside the cooling unit and sends the ap\
propriate signals to the air
conditioner control assembly.
Code No.Diag. Code Detecting ConditionTrouble area
13
Open or short in evaporator temperature sensor
circuit.Evaporator temperature sensor.
Harness or connector between evaporator
temperature sensor and A/C control
assembly.
A/C control assembly.
DIAGNOSTIC CHART
Check voltage between terminals TE
and SG of air conditioner control as-
sembly
Check evaporator temperature sensor.
Check harness and connector between air
conditioner control assembly and evapora-
tor temperature sensor (See page IN-27).
Check and replace air conditioner control
assembly. 10Proceed to next circuit inspection
shown on matrix chart (See page
AC-36
). However, when Diag. code
13 is displayed, check and replace
air conditioner control assembly.
Replace evaporator temperature
sensor.
Repair or replace harness or
connector.
AC±48±
AIR CONDITIONING SYSTEM Troubleshooting
WhereEverybodyKnowsYourName