METER AND GAUGES - Digital Type Combination Meter
-
(+) (-) OFF
Display Check (Cont'd)
a Digital combination meter is provided with a
self-check function to determine whether or
not meter itself
is malfunctioning.
Test procedure
(1) While pushing trip reset switch A, switch igni-
tion switch from
"OFF" to "ON" Trip reset
switch
A should remain pushed in until self-
check operation start
(2) Meter starts to automatically perform self-
check. Segments for meters and gauges should
illuminate one after another.
(3) If any particular segment remains off, corn-
bination meter
itself is faulty.
ACC ON -Preparation for Trouble-shooting -
0
Approx
12v 0 ov ov
SEL665D
a
Remove instrument switch
a Remove cluster lid A
Remove nut which holds instrument switch
- Trouble-shooting
I Go to "Display check" I
1 NG
power source circuit unit
-IF' L-IF-NG
Replace meter and
gauge assembly
Check for loose
harness connector
Voltmeter terminals Ignition switch position
Ohmmeter terminals
Ignition Switch OFF
Continuity exists ground
a Disconnect meter harness connector as shown
below
.
SEL744D
-
EL-47