Page 329 of 394
Downloaded from www.Manualslib.com manuals search engine TORQUE CONVERTER ( I ‘/+(I -I
1 51-Rh
CIRCUIT DIAGRAM FOR CX CONVERTER
kd i- I I I c
I I Bc Bc
*
KEY
- Existinq leads G
- Converter
6
8
;a
Parallel connecto- Mr
0 Connector with
No. of ways i
Starter
01 ---
I Bc k l3i F;J
E Mr ,L H wheelarch
A m
I 1
EMr
to TB
Ve
P n
Ve +
1 - Battery
2 - Relay for electro-valves
3 - Ignition and starting contact
4 - Electra-valve controlling fast idle
5 - Electra-valve controlling clutch
6 - Gearbox switch housing
7 - Control relay for electric fan 8 - Thermal switch corrtrolling the electric fans
9 - Electric fan
10 - Relay controlling supplementary electric fan
11 - Supplementary electric fan
12 - Warning lamp for converter oil temperature
13 - Converter oil thermal switch
Page 330 of 394
Downloaded from www.Manualslib.com manuals search engine OPERATION No MA. 510-00 b : , ,rn,l~~~‘Nl(‘Il I 0 / Ill C’ c~/~~tl,.ifNI ir/.YlnllalitM/
( j,arv 9 107j I
. Op. MA. 510-00 b
15
CIRCUIT DIAGRAM
Page 331 of 394
Downloaded from www.Manualslib.com manuals search engine CIRCUIT DIAGRAM FOR CONVERTER -AIR-CONDITIONING OPTION
L.Sl-170
Page 332 of 394

Downloaded from www.Manualslib.com manuals search engine DESCRIPTION OF COMPONENTS
1.
Battery
2. Starter
3. Anti-theft switch ignition and starting
4. Safety relay for starting and controlling the clutch electro-valve f ~/lr,c,r/(,r J
5. Clutch electro-valve ( co,/, V~IO~ J
6. Control relay for idling speeds f W//I r,~/or J
relay energized engine idling speed
- relay not energized 1 fast idling speed
7. Switch housing on gearbox ( WJ,, c,~/(,v J
8. Fast idle control relay / ~i)-c o~r/i/ir~//i,l~ 1
relay energized contact open fast idle
9. (( PIERBURG )) electro-valve for fast idle
- energized engine idle
not energized fast idle
10. I6 Amp. fuse 11.
General control relay 12.
16 Amp fuse 13.
Air blower ( tr’n~r// or c-old ) 14.
3-speed blower control
15. Regulating thermostat ( ~i,.=ror,c/i/irrr,i,l~: i
16. Air-conditioning switch 17.
Pressure switch on de-watering tank f ni,-=( or~rli/irrr/i~~~c ) 18.
Compressor clutch f nifsc o//di/io~i/l~ i 19.
Control relay for L.H supplementary electric fan (21 ) ( ~il..r~l/di/io//il/~ )
20. Control relay for electric fan (21 ) (
coolir~g o/ rficJiNlor (I nlc,r )
21. Supplementary electric fan for condenser ( ~il.~rol/ni/i~~ll/i//~ ) and water radiator ( cooling: J
22. Control relay for R.H electric fan ( 24) ( tooli~!: J
23. Thermal switch on water radiator ( (r)olir~,r~ to~trol )
24. R.H. electric fan for gearbox oil radiator and coolant radiator
25. Converter oil temperature warning lamp ( CM, c~sl~r J
26. Thermal switch for converter oil ( COMWKI~B ) KEY TO WI RING HARNESSES
No Mark
: Standard circuit (no optional equipment ) TB :
Instrument panel
Circuit for optional (( Converter - air-conditioning )) - No mark
; Converter wiring on body-shell
- CM : Converter wiring on engine
Page 333 of 394

Downloaded from www.Manualslib.com manuals search engine WIRING DIAGRAM FOR ELECTRIC FAN AND AIR-CONDITIONING CONTROL
-- I’)‘(,
L64 4
41 1 1 Front harness
-
T
17
I KEY I
I I
I
Standard wiiinq I
I I
I I
I - Air-cond wiIinq, ‘- - - - - - - _-
1 i 1 1 1
/,/r/////,/,,,,/,//////~////~‘/‘~””’~”””””~””7”“““’
Earth on gearbox
Eart>, on front L H wheelarch 1.
Control relay for supplementary electric cooling fan
2. Control relay for air blower
3. Ambient temperature thermostat ( on evaporator )
4. Air-conditioning switch (on centre console )
5. High pressure switch ( on de-watering tank )
6. Electra-magnetic clutch for compressor
7. Control electro-valve for fast idle and re-cycling ram
( WEBER electro-valve )
8. Control relay for supplementary air-conditioning electric
9. Control relay for electric cooling fan 10.
Ignition coil 11.
Idle cut-off ( on carburettor ) .12.
Electric cooling fan
13. Thermal switch for electric cut-in ( on radiator )
14. Supplementary air-conditioning electric fan
15. Air blower for air- conditioning 16.
Control resistors for air-blower speeds 17.
Air blower switch ( 3-position )
Page 334 of 394

Downloaded from www.Manualslib.com manuals search engine Op. MA. 510-00 b 17 WIRING DIAGRAMS’FOR COOLING FAN AND AIR-CONDITIONING SYSTEM CONTROL
SPECIAL FEATURES
From 1977 models the fast-idle electro-valve ( 9) is manufactured by 1, PIERBURG 1).
When it is not enerqized the electro-valve lets low pressure through towards the carburettor capsule (fast
idle ) contrary to the (1 WEBER )) electromvalve fitted previously.
Fitting the N PIERBURG )) electro-valve necessitates fitting a relay (8) which is enerqized when the air-
conditioning system is operating This relay, with its c( o/)t/i 1) contact cuts off supply to electro-valve (9)
which therefore produces fast idle. DESCRIPTION OF COMPONENTS :
1
- Heater relay ( .s/o~/~/Q~c/ )
2 - Air blower ( .S~n~~dnr(i i
3 - Speed control for blower ( S/nr/clnrt/ J
4 - Regulating thermostat
5 - Air-conditioning switch 6
- Pressure switch ( 01, dc,-rt,cr/t,rit,,q lnr~k ) 7
- Compressor clutch
8 - Control relay for fast idle melectro-valve
9 - Fast idle electro-valve lo-
Relay for L.H. supplementary electric fan f nip-cor/rli/ior/illS ) 1
I- Supplementary L.H. electric fan ( foolir2~~ ) 12-
Relay for L.H. supplementary electric fan ( cooli~/g ) ?3-
Control thermostat ( on radiator ) for electric fans ( Stnr~d& )
14- Relay for R.H. electric fan ( Stmzdnrrl )
15 Electric cooling fan ( Stal?dn~/ )
Page 335 of 394
Downloaded from www.Manualslib.com manuals search engine
Page 336 of 394
Downloaded from www.Manualslib.com manuals search engine